ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 90
S2
7
-
-
-
6
APS sensor (APS-1)
Original present
No original
5
APS sensor (APS-2)
Original present
No original
4
APS sensor (APS-3)
Original present
No original
3
APS sensor (APS-C)
Original present
No original
2
APS sensor (APS-R)
Original present
No original
1
-
-
-
0
-
-
-
S3
7
-
-
-
6
ADF/RADF tray sensor
Original present
No original
5
ADF/RADF empty sensor
Original present
No original
4
ADF/RADF opening/closing sensor
ADF/RADF
opened
ADF/RADF closed
3
ADF/RADF cover opening/closing sensor
Cover opened
Cover closed
2
ADF/RADF exit sensor
Original present
No original
1
RADF reverse sensor
Original present
No original
0
ADF/RADF read sensor
Original present
No original
S4
7
-
-
-
6
ADF/RADF registration sensor
Original present
No original
5
ADF/RADF original length sensor
Original present
No original
4
ADF/RADF original tray width sensor-1
Original present
No original
3
ADF/RADF original tray width sensor-2
Original present
No original
2
RADF original tray width sensor-3
Original present
No original
1
RADF original width detection sensor-1
Original present
No original
0
RADF original width detection sensor-2
Original present
No original
P1
7
-
-
-
6
PFP upper drawer detection switch
Drawer not
installed
Drawer present
5
-
-
-
4
PFP upper drawer feed sensor
Paper present
No paper
3
PFP connection
Connected
Not connected
2
PFP side cover opening/closing switch
Cover opened
Cover closed
1
PFP upper drawer empty sensor
No paper
Paper present
0
PFP upper drawer tray-up sensor
Tray at upper limit
position
Other than upper
limit position
P2
7
-
-
-
6
PFP lower drawer detection switch
Drawer not
installed
Drawer present
5
-
-
-
4
PFP lower drawer feed sensor
Paper present
No paper
3
PFP lower drawer empty sensor
No paper
Paper present
2
PFP lower drawer tray-up sensor
Tray at upper limit
position
Other than upper
limit position
1
ADU connection
Not connected
Connected
0
ADU entrance sensor
Paper present
No paper