FIRMWARE UPDATING
6 - 4
Note:
Note:
In case the external keyboard (GJ-1040) is used, the update must be performed after the TEL-
BOOK PC board is disconnected from the connector and the download jig is connected.
(5) Turn ON the power.
Downloading starts automatically and the processing status is displayed on the LCD.
Fig. 6-6
(6) After the update is completed properly, the LCD blinks.
Fig. 6-7
If an error occurs, the following error number is displayed and the update is interrupted. Turn
OFF the power, and then check the following items. After confirming and clearing the problems,
restart updating from the beginning.
• Is the download jig connected properly?
• Is the updating data written to the download jig properly?
• Do the download jig and the equipment operate properly?
Fig. 6-8
(7) Turn OFF the power, remove the download jig and install the connector cover.
1