ADJUSTMENT
3 - 52
3.10.2
Adjustment of ADF/RADF Height
Note:
Note:
Check if the image adjustment for the equipment is performed properly before this adjustment of
the ADF/RADF.
[A] Checking
(1) Close the ADF/RADF.
(2) Light the exposure lamp.
• Turn the power ON while pressing [1] and [3] simultaneously.
• Select [10. OUTPUT TEST] from the test menu, press the [ENTER] button.
• Key in [261], press the [ENTER] button, and then press the [START] button. Wait until the CIS
unit stops.
• Key in [267], press the [ENTER] button, and then press the [START] button to turn ON the
exposure lamp.
(3) Visually check the gap between platen guide holder “A” and upper surface of the original glass
“B” from the left hand side of the equipment. If the value is not within the tolerance, perform the
adjustment according to the following procedure.
[Tolerance of the gap]
Rear side: 0 - 0.2 mm
Front side: 0 mm
Fig. 3-50
(4) After the adjustment, press the [CANCEL] button to turn OFF the exposure lamp.
0
~
0.2mm
0mm
B
A
B