Error Code List
2.1.1
Jam
Error code
Classification
Contents
Troubleshooting
E01
Paper exit jam
Jam not reaching the exit sensor: The paper which
has passed through the fuser unit does not reach
the exit sensor.
P. 5-1
E02
Stop jam at the exit sensor: The trailing edge of the
paper does not pass the exit sensor after its leading
edge has reached this sensor.
P. 5-1
E03
Other paper jam
Power-ON jam: The paper is remaining on the
paper transport path when power is turned ON.
P. 5-2
E09
Jam at the registration area due to registration time-
out error
-
E11
Paper misfeeding
ADU misfeeding (Paper not reaching the registra-
tion sensor): The paper which has passed through
ADU does not reach the registration sensor during
duplex printing.
P. 5-7
E12
Bypass misfeeding (Paper not reaching the regis-
tration sensor): The paper fed from the bypass tray
does not reach the registration sensor.
P. 5-7
E13
Drawer misfeeding (Paper not reaching the regis-
tration sensor): The paper fed from the drawer does
not reach the registration sensor.
P. 5-8
E14
PFU drawer misfeeding (Paper not reaching the
PFU feed sensor): The paper fed from the PFU
drawer does not reach the PFU feed sensor.
P. 5-9
E15
PFP upper drawer misfeeding (Paper not reaching
the PFP upper drawer feed sensor): The paper fed
from the PFP upper drawer does not reach the PFP
upper drawer feed sensor.
P. 5-10
E16
PFP lower drawer misfeeding (Paper not reaching
the PFP lower drawer feed sensor): The paper fed
from the PFP lower drawer does not reach the PFP
lower drawer feed sensor.
P. 5-11
E21
Paper transport jam
PFU drawer transport jam (Paper not reaching the
registration sensor): The paper does not reach the
registration sensor after it has passed the PFU feed
sensor.
P. 5-3
E30
PFP upper drawer transport jam (Paper not reach-
ing the registration sensor): The paper fed from the
PFP upper drawer does not reach the registration
sensor after it has passed the PFP upper drawer
feed sensor.