e-STUDIO165/167/205/207/237
© 2006 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 66
886
Fuser
Temperature drop control
setting in ready status
(Temperature/Time)
ALL
4
<0-20>
M
0: None
1: Pattern 1
2: Pattern 2
3: Pattern 3
4: Pattern 4
5: Pattern 5
6: Pattern 6
7: Pattern 7
8: Pattern 8
9: Pattern 9
10: Pattern 10
11: Pattern 11
12: Pattern 12
13: Pattern 13
14: Pattern 14
15: Pattern 15
16: Pattern 16
17: Pattern 17
18: Pattern 18
19: Pattern 19
20: Manual adjustment
1
896-0
Fuser
Temperature
control lower
limit
(Plain paper/
Low tempera-
ture)
Center
thermistor
ALL
16 cpm /
20 cpm:
5
23 cpm :
6
<0-12>
M
0: 130°C
1: 135°C
2: 140°C
3: 145°C
4: 150°C
5: 155°C
6: 160°C
7: 165°C
8: 170°C
9: 175°C
10: 180°C
11: 185°C
12: 120°C
2
896-1
Side ther-
mistor
ALL
16 cpm /
20 cpm:
3
23 cpm :
4
<0-12>
M
2
900
Version
System firmware ROM ver-
sion
ALL
-
-
e-STUDIO165/205
JPN: T282SY0Jxxx
UC:
T282SY0Uxxx
EUR: T282SY0Exxx
Other: T282SY0xxxx
e-STUDIO167/207/237
JPN: T286SY0Jxxx
UC:
T286SY0Uxxx
EUR: T286SY0Exxx
Other: T286SY0xxxx
3
905
RADF
Process for last page (one-
sided original) at duplex
copying
PPC
0
<0-1>
-
0: One-side copy
1: Double-sided copy
(blank paper is
added to as the last
even numbered
page to output the
copy in the same ori-
entation with previ-
ous pages.)
1
906
Version
PFC firmware version
ALL
-
-
3
921
Version
FROM internal program
ALL
-
-
VTHxx.xxx
3
922
Version
Function table data version
ALL
-
-
e-STUDIO165/205
T282SY1xxxx
e-STUDIO167/207/237
T286SY1xxxx
3
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
07/02
Summary of Contents for e-STUDIO165
Page 8: ...e STUDIO165 167 205 207 237 2006 2008 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Page 10: ......
Page 312: ......
Page 313: ......