TROUBLESHOOTING
5 - 35
5
8) Solid copy
Fig. 5-8
Defective area
Step
Check items
Prescription
Scanner
1
Does the exposure lamp light?
Check if the connector contacts with
the MAIN board and CIS unit termi-
nal.
Bedewed scanner and
drum
2
Is the scanner or drum bedewed?
Clean the CIS unit and drum.
Keep the power cord plugged in all
trough the day and night.
(For the model with damp heater)
Main charger
3
Is the main charger securely
installed?
Install it securely.
4
Is the needle electrode broken?
Replace the needle electrode.
High-voltage transformer
(Main charger)
5
Is the high-voltage transformer out-
put defective?
Adjust the output, or replace the
transformer.
6
Are the connectors of the high-volt-
age harness securely connected? Is
the harness open circuited?
Reconnect the harness securely.
Replace the high-voltage harness.
MAIN, LDR, SNS boards,
CIS unit and harnesses
7
Are the connectors securely con-
nected?
Check if the harnesses connecting
the boards are open circuited.
Connect the connectors securely.
Replace the harness.