e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 7
8
01
Developing bias output
(DVLP BIAS SET.)
[Function]
When [OK (ENTER)/START] key is pressed, the developing bias signal is turned ON for 30sec.
When, however, an actual output value is measured, use test command 25-01.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
02
Main charger output (Grid
HIGH) (MHV(H) SET.)
[Function]
When [OK (ENTER)/START] key is pressed, the main charger is outputted for 30sec in the grid volt-
age HIGH move.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
03
Main charger output (Grid
LOW) (MHV(L) SET.)
[Function]
When [OK (ENTER)/START] key is pressed, the main charger is outputted for 30sec in the grid volt-
age LOW move.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
06
Transfer charger output
(THV SET.)
[Function]
When [OK (ENTER)/START] key is pressed, the transfer charger is outputted for 30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
9
01
Duplex motor normal
rotation check (DPLX ROT.)
(Enabled when Duplex
setting is ON) (Executable
only when the RADF is
installed.)
[Function]
Use the duplex motor Bios to drive the duplex motor in the normal direction (paper exit direction) for
30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
02
Duplex motor reverse
rotation check (DPLX
ROT.REV.) (Enabled when
Duplex setting is ON)
(Executable only when the
RADF is installed.)
[Function]
Use the duplex motor Bios to drive the duplex motor in the reverse direction for 30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
04
Duplex motor rotating speed
adjustment (DPLX
ROT.SPEED) (Enabled
when Duplex setting is ON)
(Executable only when the
RADF is installed.)
[Function]
When this Test Command is executed, the currently set value is displayed.
Enter the adjustment value with [10KEY] and press [START] key. The entered value is stored and the
machine goes into the sub code entry standby mode. The greater the set value is, the higher the
speed is. The smaller the set value is, the lower the speed is. (Setting range: 1 - 13, Default: 8)
[Operation]
Main
code
Sub
code
Contents
Details of function/operation
1) Initial display
08-01 DVLP BIAS SET.
EXECUTING...
1) Initial display
08-02 MHV(H) SET.
EXECUTING...
1) Initial display
08-03 MHV(L) SET.
EXECUTING...
1) Initial display
08-03 THV SET.
EXECUTING...
1) Initial display
09-01 DPLX ROT.
EXECUTING...
1) Initial display
09-02 DPLX ROT.REV.
EXECUTING...
1) Initial display
2) [10KEY]
3) [OK (ENTER)/START]
09-04 DPLX ROT.SPEED
8( 1-13)
09-04 DPLX ROT.SPEED
7( 1-13)
09-04 DPLX ROT.SPEED
7( 1-13)
e-STUDIO162_151.book 7
ページ
2004年12月2日 木曜日 午後9時37分