e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 16
41
06
OC cover float detection
level (OC FLOAT LEVEL)
(Disabled when set to OC)
(Executable only when the
ADF/RADF is installed.)
[Function]
When this test command is executed, the current set value is displayed. When [OK (ENTER)/START]
key is pressed, the mirror base unit moves to the ADF scan position to acquire the OC cover float
detection level.
When the mirror base unit returns to the home position, the acquired value is displayed.
If the detection level is not acquired, ERR display is made. (Default: 0)
Note that, this test command must be executed with the OC cover closed.
∗
If the value is 0, float detection is not performed in normal jobs.
[Operation]
43
01
Fusing temperature setting
(Normal copy) (FU TEMP)
[Function]
When this test command is executed, the current set code number is displayed. Press [
←
/
→
/10KEY]
key to change the setting and press [OK (ENTER)/START] key to save the setting into the EERPOM.
The machine goes into the sub code entry standby mode.
[Operation]
The operation is similar to test command 21-01.
04
Fusing temperature setting
in multi coy (FU TEMP
MULTI)
[Function]
For 20th sheet or later in multi copy, the fusing temperature is automatically changed from the temper-
ature set with test command 43-1 to the temperature set with this test command.
When this test command is executed, the current set code number is displayed. Enter the code num-
ber and press [OK (ENTER)/START] key to change the setting.
[Operation]
The operation is similar to test command 21-01.
Main
code
Sub
code
Contents
Details of function/operation
1) Initial display
2) [OK (ENTER)/START]
41-06 OC FLOAT LEVEL
0
41-06 OC FLOAT LEVEL
EXECUTING...
<Canceling - when C/CA key is pressed->
After canceling, the machine goes into the sub code entry
standby mode.
3) When the level is acquired:
3) When the level is not acquired:
THE JOB IS BEING
CANCELED.
41-06 OC FLOAT LEVEL
**** OK
41-06 OC FLOAT LEVEL
**** ERR
Code
Set temperature (°C)
Remark
0
160
1
165
2
170
3
175
4
180
5
185
6
190
Default
7
195
8
200
Code
Set temperature (°C)
Remark
0
155
1
160
2
165
3
170
Default
4
175
5
180