e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 2
24
01
JAM total counter clear (JAM TTL CLR.)
04
ADF counter clear (ADF CLR.) (Disabled when set to
OC) (Executable only when the ADF is installed.)
05
Duplex counter clear (DPLX CLR.) (Enabled when
Duplex setting is ON)
06
Developer counter clear (DVLP CLR.)
07
Drum counter clear (DRUM CLR.)
08
Copy counter clear (COPIES CLR.)
09
Printer counter clear (PRT.CLR.)
10
FAX counter clear (FAX CLR.) (Executable only when the
FAX is installed.)
13
Scanner counter clear (SCAN CLR.)
14
ADF JAM total counter clear (S JAM TTL CLR.)
(Disabled when set to OC) (Executable only when the
ADF is installed.)
15
Scanner mode counter clear (S-MODE CLR.)
25
01
Main motor operation check (MAIN MOTOR CHK)
10
Polygon motor operation check (LSU CHK)
26
02
(R)ADF setting (ADF/RADF) (Executable only when the
ADF/RADF is installed.)
03
Second cassette setting (2ND TRAY)
04
Main unit duplex setting (DPLX) (Executable only when
the RADF is installed.)
06
Destination setting (DESTINATION)
07
Machine conditions check (CPM)
20
Rear edge void setting (END EDGE)
30
CE mark support control ON/OFF (CE MARK)
37
Cancel of stop at developer life over (DVLP LIFE END)
39
Memory capacity check (MEM.CHK)
40
Polygon motor OFF time setting (Time required from
completion of printing to turning OFF the motor) (LSU
MOTOR OFF)
42
Transfer ON timing control setting (TC ON TIMING)
43
Side void amount setting (SIDE VOID)
62
Energy-save mode copy lamp setting (C-LAMP E-S)
30
01
Paper sensor status display (P-SENSOR)
41
06
OC cover float detection level (OC FLOAT LEVEL)
(Disabled when set to OC) (Executable only when the
ADF/RADF is installed.)
43
01
Fusing temperature setting (Normal copy) (FU TEMP)
04
Fusing temperature setting in multi coy (FU TEMP
MULTI)
05
Fusing temperature setting in duplex copy (FU TEMP
DPLX) (Enabled when Duplex setting is ON)
14
Fusing start temperature setting (FU TEMP START)
46
01
Copy density adjustment (300dpi) (EXP.LEVEL 300)
02
Copy density adjustment (600dpi) (EXP.LEVEL 600)
12
Density adjustment in the FAX mode (Collective
adjustment) (Executable only when the FAX is installed.)
13
FAX mode density adjustment (normal text) (Executable
only when the FAX is installed.)
14
FAX mode density adjustment (Fine text) (Executable
only when the FAX is installed.)
15
FAX mode density adjustment (Super fine) (Executable
only when the FAX is installed.)
18
Image contrast adjustment (300dpi) (GAMMA 300)
19
Exposure mode setting (AE MODE)
20
ADF exposure correction (EXP.LEVEL ADF) (Disabled
when set to OC) (Executable only when the ADF is
installed.)
29
Image contrast adjustment (600dpi) (GAMMA 600)
30
AE limit adjustment (AE LIMIT)
31
Image sharpness adjustment (SHARPNESS)
Main
code
Sub
code
Contents
46
32
Copier color reproduction setting (COLOR REAPPEAR)
39
FAX mode sharpness adjustment (Executable only when
the FAX is installed.)
48
01
Mains can/sub scan direction magnification ratio (COPY
MAG.)
05
ADF/RADF mode sub scan direction magnification ratio
in copying (ADF/RADF MAG.) (Disabled when set to OC)
(Executable only when the ADF/RADF is installed.)
49
01
Download mode (DOWNLOAD MODE)
50
01
Lead edge image position (LEAD EDGE)
06
Copy lead edge position adjustment (ADF/RADF) (ADF/
RADF EDGE) (Disabled when set to OC) (Executable
only when the ADF/RADF is installed.)
10
Print center offset adjustment (PRT.OFF-CENTER)
12
Document feed off-center adjustment (ORG.OFF-
CENTER)
18
Memory reverse position adjustment in duplex copy
(DPLX REVERSE) (Enabled when Duplex setting is ON
with OC or ADF set) (Executable only when the RADF is
installed.)
19
Duplex copy rear edge void adjustment (DPLX END
EDGE) (Enabled when Duplex setting is ON) (Executable
only when the RADF is installed.)
51
02
Resist amount adjustment (RESIST ADJ.)
53
08
ADF scan position automatic adjustment (ADF AUTO)
(Disabled when set to OC) (Executable only when the
ADF is installed.)
61
03
HSYNC output check (LSU CHK)
63
01
Shading check (SHADING CHK)
02
Black level automatic correction (BLACK LEVEL)
64
01
Self print (1by2 mode) (SELF PRT.)
66
01
FAX soft SW setting (Executable only when the FAX is
installed.)
02
FAX soft SW initializing (excluding the adjustment
values) (Executable only when the FAX is installed.)
03
FAX PWB memory check (Executable only when the
FAX is installed.)
04
Signal send mode (Max. value) (Executable only when
the FAX is installed.)
05
Signal send mode (Soft SW set value) (Executable only
when the FAX is installed.)
07
Image memory content print (Executable only when the
FAX is installed.)
10
Image memory content clear (Executable only when the
FAX is installed.)
11
300bps signal send (Max. value) (Executable only when
the FAX is installed.)
12
300bps signal send (Soft SW set value) (Executable only
when the FAX is installed.)
13
Dial test (Executable only when the FAX is installed.)
17
DTMF signal send (Max. value) (Executable only when
the FAX is installed.)
18
DTMF signal send (Soft SW set value) (Executable only
when the FAX is installed.)
21
FAX information print (Executable only when the FAX is
installed.)
24
FAST SRAM clear (Executable only when the FAX is
installed.)
30
TEL/LIU status change check (Executable only when the
FAX is installed.)
32
Receive data check (Executable only when the FAX is
installed.)
33
Signal detection check (Executable only when the FAX is
installed.)
Main
code
Sub
code
Contents
e-STUDIO162_151.book 2
ページ
2004年12月2日 木曜日 午後9時37分
Summary of Contents for e-studio 151
Page 170: ...Memo ...
Page 171: ...Memo ...
Page 172: ...Memo ...
Page 176: ...2 17 2 HIGASHIGOTANDA SHINAGAWA KU TOKYO 141 8664 JAPAN ...