e-STUDIO162/162D/151/151D EXTERNAL VIEWS AND INTERNAL STRUCTURES 4 - 4
5. Sensors and switches
(With optional ADF/RADF installed)
No.
Name
Signal
Type
Function
Output
1
Scanner unit home position
sensor
MHPS
Photointerrupter
Scanner unit home position detection
"H" at home position
2
POD sensor
POD
Photointerrupter
Paper exit detection
"H" at paper pass
3
PPD2 sensor
PPD2
Photointerrupter
Paper transport detection 2
"L" at paper pass
4
Cassette detection switch
CED1
Micro-switch
Cassette installation detection
"H" at cassette insertion
5
PPD1 sensor
PPD1
Photointerrupter
Paper transport detection 1
"L" at paper pass
6
Door switch
DSW
Micro-switch
Door open/close detection
(safety switch for 24V)
1 or 0V of 24V at door open
7
ADF sensor
SPID/
SD SW
Photointerrupter
Paper entry detection
Cover open/close detection
"L" at paper pass
8
SPPD sensor
SPPD
Photointerrupter
Paper transport detection
"L" at paper pass
9
PD1 sensor
PD1
Micro-switch
Paper width detect
"H" at A4 size or less
"L" at A4 size or more
1
8
7
2
3
4
5
9
6
04_EXTER.fm 4