Autoped Installation Manual rev 2.0 (100722)
62
Error No
Description
Cause
Elimination
Checking Time
Reaction
E14 01
Locking/Electr
ic lock
The Door/Gate got caught in
the locking/electric lock
Check the function of the
locking/electric lock
When opening from
a closed position
H
02
The inverted operation has
no locking, or the
interlocking force Fch has
not been programmed
Program/increase the interlocking
force Fch
At the end of the
teach procedure
W
E15 01
Obstacle
during
opening
Too many successive
obstacles have occurred
•
Examine the installation
•
Remove the obstacle
•
Move the Door/Gate to the
target position
Permanent
H, A
Restart after
60 seconds
02
Obstacle
during closing
E16 01
Temperature
Temperature on output level
has reached 178°F
Allow the unit to cool down
Permanent
A
Drive unit
functions
with
reduced
power
02
Temperature on output level
has reached 196°F
A
Drive unit
has stopped
E20 01
SER test
(Swing side
safety)
SER test signal unsuccessful SER short circuit to the earth.
Check the cabling of the sensor or
the jumper
Prior to closing
A
02
SER too slow
SER reacts too slowly. Check the
cabling for the sensor. Check for
polarity reversal/test signal.
E20-01 and E20-02
together, no line in
between, like E21
E21 01
SES test
(Push side
safety)
SES test signal unsuccessful SES short circuit to the earth.
Check the cabling of the sensor or
the jumper.
Prior to opening
A
02
SES too slow
SES reacts too slowly. Check the
cabling of the sensor. Check for
polarity reversal/test signal.
Summary of Contents for AUTOPED M10S.0028
Page 1: ...Autoped Installation Manual rev 2 0 100722 1 AUTOPEDTM OPERATOR INSTALLATION MANUAL 2022...
Page 40: ...Autoped Installation Manual rev 2 0 100722 40 SECTION X SETTING UP ELECTRIC LOCKS AND STRIKES...
Page 50: ...Autoped Installation Manual rev 2 0 100722 50 SECTION XII MENUS AND PROGRAMMING...
Page 59: ...Autoped Installation Manual rev 2 0 100722 59 SECTION XIII TROUBLE SHOOTING AND ERROR CHARTS...
Page 69: ...Autoped Installation Manual rev 2 0 100722 69 Fig XIV 2b Non Powered Activation Devices...
Page 75: ...Autoped Installation Manual rev 2 0 100722 75 Fig XIV 2f Secured Activation Devices...
Page 76: ...Autoped Installation Manual rev 2 0 100722 76 Fig XIV 2g Wiring for Double Door Gate System...
Page 77: ...Autoped Installation Manual rev 2 0 100722 77 SECTION XV SERVICE PARTS...
Page 78: ...Autoped Installation Manual rev 2 0 100722 78 XV 1 SERVICE PARTS COMPONENTS VISUAL GUIDE...
Page 80: ...Autoped Installation Manual rev 2 0 100722 80 SECTION XVI PRODUCT WARRANTY AND REGISTRATION...