maximum is 9.
⚠
TORXUN recommends setting Vo between 1-3 for initial set up. Once the
operation of the gate is confirmed, then the desired speed can be finalized in
compliance with ANSI 156.19.
⚠
STEP 10: Vc
o
Vc controls the Velocity/speed at which the gate closes.
o
Default is set to 9, use the joystick left and right to select the desired speed. Press
the joystick in to confirm the selection; i.e. In LowEn ON mode, the selection
maximum is 9
⚠
TORXUN recommends setting Vc between 1-3 for the initial set up. Once the
operation of the gate is confirmed, then the desired speed can be finalized in compliance with
ANSI 156.19
⚠
STEP 11: Invers
o
Using the joystick left
and right, set Invers to “OFF”. Press the joystick in to confirm
the selection.
o
Invers refers to configuring the Door/Gate to open when power is lost. In such rare
applications the gate will default (spring) to open and operate to close.
STEP 12: Teach
o
Press the joystick in to move to the next selection.
o
“Teach ok?” will appear on the screen
o
Press the joystick in again and you will hear beeping as well as see a ten (10) second countdown on the screen.
o
Once the countdown ends, the gate will open, pause, and then close while beeping. If no errors occur, the LCD display will
display “Done!” with “E11” underneath it.
o
E11 requires the operator to be run through one more full Open and Close cycle via activation command to confirm the
settings.
⚠
ATTENTION: At this point, clear the area of any persons or objects in the path of the gate to avoid injuries or
damages. Proceed to the next step once the path of the gate is clear.
⚠
Summary of Contents for AUTOPED M10S.0028
Page 1: ...Autoped Installation Manual rev 2 0 100722 1 AUTOPEDTM OPERATOR INSTALLATION MANUAL 2022...
Page 40: ...Autoped Installation Manual rev 2 0 100722 40 SECTION X SETTING UP ELECTRIC LOCKS AND STRIKES...
Page 50: ...Autoped Installation Manual rev 2 0 100722 50 SECTION XII MENUS AND PROGRAMMING...
Page 59: ...Autoped Installation Manual rev 2 0 100722 59 SECTION XIII TROUBLE SHOOTING AND ERROR CHARTS...
Page 69: ...Autoped Installation Manual rev 2 0 100722 69 Fig XIV 2b Non Powered Activation Devices...
Page 75: ...Autoped Installation Manual rev 2 0 100722 75 Fig XIV 2f Secured Activation Devices...
Page 76: ...Autoped Installation Manual rev 2 0 100722 76 Fig XIV 2g Wiring for Double Door Gate System...
Page 77: ...Autoped Installation Manual rev 2 0 100722 77 SECTION XV SERVICE PARTS...
Page 78: ...Autoped Installation Manual rev 2 0 100722 78 XV 1 SERVICE PARTS COMPONENTS VISUAL GUIDE...
Page 80: ...Autoped Installation Manual rev 2 0 100722 80 SECTION XVI PRODUCT WARRANTY AND REGISTRATION...