VIII.1 ADJUSTING THE CLOSING-SPRING PRELOAD
The AutoPed operator is equipped with a closing spring that aids in the closure of the gate/door and to keep closing speeds while the
gate/door is in manual mode. When power to the operator is cut or turned off, the closing spring will allow the Door/Gate to close in a
controlled manner, fully latching the door lock system.
The tension of the spring regulates the amount of pressure the door requires to be pushed open.
Preload adjustment is done by turning the Adjusting Screw. By default, distance
X
between top of head of Adjusting Screw and spring
bracket is:
X
= 1-1/32 inch (26 mm)
Summary of Contents for AUTOPED M10S.0028
Page 1: ...Autoped Installation Manual rev 2 0 100722 1 AUTOPEDTM OPERATOR INSTALLATION MANUAL 2022...
Page 40: ...Autoped Installation Manual rev 2 0 100722 40 SECTION X SETTING UP ELECTRIC LOCKS AND STRIKES...
Page 50: ...Autoped Installation Manual rev 2 0 100722 50 SECTION XII MENUS AND PROGRAMMING...
Page 59: ...Autoped Installation Manual rev 2 0 100722 59 SECTION XIII TROUBLE SHOOTING AND ERROR CHARTS...
Page 69: ...Autoped Installation Manual rev 2 0 100722 69 Fig XIV 2b Non Powered Activation Devices...
Page 75: ...Autoped Installation Manual rev 2 0 100722 75 Fig XIV 2f Secured Activation Devices...
Page 76: ...Autoped Installation Manual rev 2 0 100722 76 Fig XIV 2g Wiring for Double Door Gate System...
Page 77: ...Autoped Installation Manual rev 2 0 100722 77 SECTION XV SERVICE PARTS...
Page 78: ...Autoped Installation Manual rev 2 0 100722 78 XV 1 SERVICE PARTS COMPONENTS VISUAL GUIDE...
Page 80: ...Autoped Installation Manual rev 2 0 100722 80 SECTION XVI PRODUCT WARRANTY AND REGISTRATION...