Autoped Installation Manual rev 2.0 (100722)
53
TLock
Low energy
0.5s
0.0-4.0s
Sets amount of time Door/Gate panel will press against lock to engage
it.
Flock
Low energy
2.0A
Off-7.0A
Sets amount of force applied to the Door/Gate panel to engage the
lock at the closed position. It is only active if TLock setting is greater
than 0.
FSlam
Low energy
Off
Off-10
Accelerating function (Force Slam). For example: when a Door/Gate
panel needs to be forced shut due to a latch or heavy seals.
FWind
Low energy
Off
Off
❖
Wind load detection optimized for exterior doors/gate panels
❖
Assuming that a gust of wind is not a hard obstacle which will stop
the door, the
motor current will rise “slowly.” In this case the
AutoPed control unit will supply additional power to continue the
door movement.
❖
When FWind is turned ON, TORXUN strongly recommends the
use of Door/Gate panel mounted sensors to stop or reopen the
door if an obstacle is detected during the door cycle
Open
Close
Both
Fo
Low energy
9
0-9
❖
Opening force (force open) when an obstacle is detected during
open/close cycle or both
❖
In standard mode obstacle detection cannot be switched on/off. It
can be adjusted with parameters for
“Fo”=force opening and
“Fc”=force close. To make obstacle detection least sensitive, set
both parameters on 9. To make obstacle detection most sensitive,
set both parameters on 0. (Caution, this can allow the drive to
react to slight changes in wind)
Fc
Low energy
9
0-9
Foh
Low energy
4
0-9
Hold open force (force hold open)
Fch
Low energy
0.0A
0.0A-3.5A
❖
Interlocking force (force close hold) automatically programs Flock
and FDelay if these settings are set at 0.
❖
If there is no electric lock and the interlocking force Fch is not
adjusted, error 14/02 will be displayed as a warning after the teach
1 procedure and the Door/Gate will endlessly reopen.
LowEn
Low energy
On
On
Door/Gate panel is low energy in both directions. Door/Gate panel is
activated by a knowing act.
Width
Low energy
48in
30-63in
Width of the Door/Gate panel from edge to edge.
⚠
UL approval for
maximum width of 63
”
⚠
Weight
Low energy
100~250lbs 100-550lbs
Weight of the Door/Gate panel.
⚠
UL approval for 250lbs
⚠
Ao
Low energy
95°
20°-190°
Opening angle of the door (angle open)
Teach must be activated after this setting has been changed
Summary of Contents for AUTOPED M10S.0028
Page 1: ...Autoped Installation Manual rev 2 0 100722 1 AUTOPEDTM OPERATOR INSTALLATION MANUAL 2022...
Page 40: ...Autoped Installation Manual rev 2 0 100722 40 SECTION X SETTING UP ELECTRIC LOCKS AND STRIKES...
Page 50: ...Autoped Installation Manual rev 2 0 100722 50 SECTION XII MENUS AND PROGRAMMING...
Page 59: ...Autoped Installation Manual rev 2 0 100722 59 SECTION XIII TROUBLE SHOOTING AND ERROR CHARTS...
Page 69: ...Autoped Installation Manual rev 2 0 100722 69 Fig XIV 2b Non Powered Activation Devices...
Page 75: ...Autoped Installation Manual rev 2 0 100722 75 Fig XIV 2f Secured Activation Devices...
Page 76: ...Autoped Installation Manual rev 2 0 100722 76 Fig XIV 2g Wiring for Double Door Gate System...
Page 77: ...Autoped Installation Manual rev 2 0 100722 77 SECTION XV SERVICE PARTS...
Page 78: ...Autoped Installation Manual rev 2 0 100722 78 XV 1 SERVICE PARTS COMPONENTS VISUAL GUIDE...
Page 80: ...Autoped Installation Manual rev 2 0 100722 80 SECTION XVI PRODUCT WARRANTY AND REGISTRATION...