Removing the Rate Control
Manifold Valve
1.
Remove 2 flange clamps and 2 gaskets that
secure the manifold for the rate control valve
(
) to the pressure filter and agitation
valve.
Note:
Retain the flange clamps and gaskets
for installation in
Manifold Valve (page 83)
.
g033584
Figure 110
1.
Flange (pressure filter
head)
4.
Flange clamp
2.
Manifold (rate control
valve)
5.
Gasket
3.
Flange (agitation valve)
6.
3-pin connector (valve
actuator—rate control
valve)
2.
Remove the retainer that secure the outlet fitting
to the manifold coupling for the rate control valve
(
g033585
Figure 111
1.
Flange-head bolt (1/4 x
3/4 inch)
4.
Retainer
2.
Valve mount
5.
Socket (outlet fitting)
3.
Flange locknut (1/4 inch)
6.
Coupling (manifold—rate
control valve)
3.
Remove the 2 flange-head bolts (1/4 x 3/4 inch)
and 2 flange locknuts (1/4 inch) that secure
the rate control valve to the valve mount and
remove the valve manifold from the machine
(
Note:
If necessary, loosen the mounting
hardware for the pressure filter head to ease
removal of the rate control valve.
Note:
Retain the flange-head bolts, flange
locknuts, and retainer for installation in
the Rate Control Manifold Valve (page 83)
.
77