4.
Press down on the accelerator pedal until the
engine reaches maximum speed.
5.
Set the engine speed as follows:
•
For machines
without
the optional throttle
lock—have 1 person press down on the
accelerator pedal until the engine reaches
maximum speed.
Note:
Have the other person collect
samples from the sprayer nozzles.
•
For machines
with
the optional throttle lock,
press down on the accelerator pedal until the
engine reaches maximum speed and set the
throttle lock; refer to operation instructions
for your Workman hand throttle kit.
6.
Set all 3 boom switches and the master-boom
switch to the O
N
position.
7.
Prepare to perform a catch test using the
graduated container.
8.
Start at 2.75 bar (40 psi) and use the
application-rate switch to adjust the spray
pressure so a catch test yields the amounts
listed in the table that follows.
Note:
Collect 3 samples at 15 seconds each
and average the quantities of water collected.
Nozzle
Color
Milliliters collected in
15 seconds
Ounces collected in
15 seconds
Yellow
189
6.4
Red
378
12.8
Brown
473
16.0
Gray
567
19.2
White
757
25.6
Blue
946
32.0
Green
1,419
48.0
9.
Once the catch test has yielded the amounts
listed in the table above, set the supervisor
rate-lockout switch to the L
OCK
position.
10.
Turn the master boom switch to the O
FF
position.
11.
On the InfoCenter, navigate to the Calibration
menu and select Flow Calibration as follows:
Note:
Selecting the Home Screen icon at any
time cancels calibrations.
A.
Press the center button of the info center
twice to access the menus.
B.
Enter the calibration menu by pressing the
right button on the info center.
C.
Select Flow Cal by highlighting Flow Cal
and press the right button on the InfoCenter.
D.
In the next screen, enter the known quantity
of water that should spray out of the booms
for the calibration procedure; refer to the
chart below.
E.
Once the known quantity has been entered
press the right button on the info center.
12.
Using the plus (+) and minus (-) symbols, enter
the flow volume according to the table that
follows.
Nozzle
Color
Liters
US Gallons
Yellow
42
11
Red
83
22
Brown
106
28
Gray
125
33
White
167
44
Blue
208
55
Green
314
83
13.
Turn the master boom switch to the O
N
position
for 5 minutes.
Note:
As the machine sprays, the InfoCenter
displays the quantity of fluid that it is counting.
14.
After 5 minutes of spraying, click the check mark
by pressing the center button on the InfoCenter.
Note:
It is acceptable if the gallons displayed
during the calibration process do not match
the known quantity of water entered into the
InfoCenter.
15.
After 5 minutes, turn the master boom switch to
the O
FF
position and select the check mark on
the InfoCenter.
Note:
Calibration is now complete.
Calibrating the Sprayer Speed
1.
Ensure that the sprayer tank is filled with water.
2.
On an open, flat area, mark off a distance
between 45 to 152 m (150 to 500 ft).
Note:
Mark off 152 m (500 ft) for more accurate
results.
3.
Start the engine and drive to the start of the
marked-off distance.
Note:
Align the center of the front tires with the
starting line for the most accurate measurement.
4.
On the InfoCenter, navigate to the Calibration
menu and select Speed Calibration.
Note:
Selecting the Home Screen icon at any
time cancels the calibration.
5.
Select the Next arrow (→) on the InfoCenter.
61