Inspecting the Nylon Pivot
Bushings
Service Interval:
Every 400 hours/Yearly (whichever
comes first)
1.
Park the machine on a level surface, engage the
parking brake, shut off the pump, shut off the
engine, and remove the key.
2.
Extend the booms to the spray position and
support the booms using stands or straps from
a lift.
3.
With the weight of the boom supported, remove
the bolt and nut securing the pivot pin to the
boom assembly (
).
g022367
Figure 107
1.
Nylon bushings
3.
Bolt
2.
Pivot pin
4.
Remove the pivot pin.
5.
Remove the boom and pivot bracket assembly
from the center frame to access the nylon
bushings.
6.
Remove and inspect the nylon bushings from
the front and back sides of the pivot bracket
(
).
Note:
Replace any damaged bushings.
7.
Place a small amount of oil on the nylon
bushings, and install them into pivot bracket.
8.
Install the boom and pivot bracket assembly into
the center frame, aligning the openings (
9.
Install the pivot pin and secure it with the bolt
and nut removed previously.
Repeat this procedure for each boom.
Cleaning
Cleaning the Flow meter
Service Interval:
Every 200 hours/Yearly (whichever
comes first) (more often when using
wettable powders).
1.
Thoroughly rinse and drain the entire spraying
system.
2.
Remove the flow meter from the sprayer and
flush it with clean water.
3.
Remove the retainer ring on the upstream side
(
).
g214630
Figure 108
1.
Flange (flow-meter body)
7.
Upstream hub and bearing
(with keyway up)
2.
Downstream hub (with
keyway up)
8.
Turbine stud
3.
Retaining ring
9.
Wire-harness clamp
4.
Down stream arrow
(flow-meter body)
10.
Flange-head screw
5.
Upstream
11.
Sensor assembly
6.
Rotor/magnet
4.
Clean the turbine and the turbine hub to remove
metal filings and any wettable powders.
5.
Inspect the turbine blades for wear.
Note:
Hold the turbine in your hand and spin
it. It should spin freely with very little drag. If it
does not, replace it.
6.
Assemble the flow meter.
7.
Use a low pressure (50 kPa or 5 psi) air jet to
ensure that the turbine spins freely.
Note:
If the turbine does not spin freely, loosen
the hex stud on the bottom of the turbine hub by
1/16 of a turn until it does spins freely.