Agitation Bypass Valve Knob
Positions
•
The agitation bypass valve is in the full Open
position as shown in
•
The agitation bypass valve is in the Closed (0)
position as shown in
•
The agitation bypass valve is in an intermediate
(adjusted relative to the pressure gauge for the
sprayer system) position as shown in
C.
g214029
Figure 88
1.
Open
3.
Intermediate position
2.
Closed (0)
Calibrating the Agitation Bypass
Valve
Service Interval:
Yearly
Important:
Select an open flat area to perform
this procedure.
Note:
Calibrating the agitation bypass valve for
machines without a throttle lock
requires 2 people.
1.
Ensure that the sprayer tank is filled with water.
2.
Verify the agitation-control valve is open. If it has
been adjusted, open it completely at this time.
3.
Set the transmission as follows:
•
For HD-Series Models with a
manual
transmission
—shift the transmission to the
N
EUTRAL
position.
•
For the
HDX-Auto model
—shift the
transmission to P (park).
4.
Engage the parking brake and turn the engine
on.
5.
Turn on the sprayer pump.
6.
Set the engine speed as follows:
•
For machines
without
the optional throttle
lock—have 1 person press down on the
accelerator pedal until the engine reaches
maximum speed.
Note:
Have the other person collect
samples from the sprayer nozzles.
•
For machines
with
the optional throttle lock,
press down on the accelerator pedal until the
engine reaches maximum speed and set the
throttle lock; refer to operation instructions
for your Workman hand throttle kit.
7.
Set the 3 individual boom valves to the O
FF
position.
8.
Set the master boom switch to the O
N
position.
9.
Set the system pressure to Maximum.
10.
Press the agitation switch to the O
FF
position
and read the pressure gauge.
•
If the reading remains at 6.9 bar (100 psi) the
agitation bypass valve is properly calibrated.
•
If the pressure gauge reads differently
continue to the next step.
11.
Adjust the agitation bypass valve (
on the backside of the agitation valve until the
pressure reading on the gauge is 6.9 bar (100
psi).
g033583
Figure 89
1.
Agitation bypass valve
2.
Master-boom bypass
12.
Press the pump switch to the O
FF
position, shift
the throttle lever to the I
DLE
position, and turn
the starter switch to the O
FF
position.
Adjusting the Master-Boom
Bypass Valve
Note:
Adjusting the master-boom bypass valve
reduces or increases the amount of flow sent to the
63