6.
Using the plus (+) and minus (-) symbols, enter
the marked-off distance into the InfoCenter.
7.
Perform one of the following:
•
For HD-Series Models with a
manual
transmission
—shift the machine into first
gear and drive the marked distance in a
straight line at full throttle.
•
For the
HDX-Auto model
,—shift the
machine into D (drive) and drive the marked
distance in a straight line at full throttle.
8.
Stop the machine at the marked-off distance
and select the check mark on the InfoCenter.
Note:
Slow down and roll to a stop to align the
center of the front tires with the finish line, for
the most accurate measurement.
Note:
Calibration is now complete.
Calibrating the Boom Bypass
Important:
Select an open flat area to perform
this procedure.
Note:
Calibrating the boom bypass for
machines
without a throttle lock
requires 2 people.
1.
Ensure that the sprayer tank is filled with water.
2.
Set the transmission as follows:
•
For HD-Series Models with a
manual
transmission
—shift the transmission to the
N
EUTRAL
position.
•
For the
HDX-Auto model
—shift the
transmission to P (park).
3.
Engage the parking brake and turn the engine
on.
4.
Set the 3 boom switches to the O
N
position,
but leave the master boom switch in the O
FF
position.
5.
Set the pump switch to the O
N
position, and turn
on the agitation.
6.
Set the engine speed as follows:
•
For machines
without
the optional throttle
lock—have 1 person press down on the
accelerator pedal until the engine reaches
maximum engine speed.
Note:
Have the other person adjust the
boom section-bypass valves.
•
For machines
with
the optional throttle lock,
press down on the accelerator pedal until
the engine reaches maximum engine speed
and set the throttle lock; refer to operation
instructions for your Workman hand throttle
kit.
7.
On the InfoCenter, navigate to the Calibration
menu and select Test Speed.
Note:
Selecting the Home Screen icon at any
time cancels calibration.
8.
Using the plus (+) and minus (–) symbols, enter
a test speed of 5.6 km/h (3.5 mph), then select
the Home icon.
9.
Using the application rate switch, adjust the
application rate according to the table that
follows.
Nozzle Application Rate Table
Nozzle Color
SI (Metric)
English
Turf
Yellow
159 L/ha
17 gpa
0.39 gpk
Red
319 L/ha
34 gpa
0.78 gpk
Brown
394 L/ha
42 gpa
0.96 gpk
Gray
478 L/ha
51 gpa
1.17 gpk
White
637 L/ha
68 gpa
1.56 gpk
Blue
796 L/ha
85 gpa
1.95 gpk
Green
1,190 L/ha
127 gpa
2.91 gpk
10.
Turn off the left boom and adjust the boom
bypass valve (
) until the pressure
reading is at the previously adjusted level
(typically 2.75 bar or 40 psi).
Note:
The numbered indicators on the bypass
valve are for reference only.
g028047
Figure 87
1.
Boom-bypass adjustment
11.
Turn on the left boom and turn off the right boom.
12.
Adjust the right boom bypass valve (
until the pressure reading is at the previously
adjusted level (typically 2.75 bar or 40 psi).
13.
Turn on the right boom and turn off the center
boom.
14.
Adjust the center boom bypass valve (
until the pressure reading is at the previously
adjusted level (typically 2.75 bar or 40 psi).
15.
Turn all the booms off.
16.
Turn the pump off.
Note:
Calibration is now complete.
62