5.
Move the section-valve manifold and gaskets
down to clear the section-bypass valve and then
away from the machine (
).
Note:
If needed, loosen the mounting hardware
for the left or right section-valve manifolds as
needed to provide clearance.
Note:
Retain the flange clamps, gaskets and
quick-connect pins for installation in
the Agitation-Manifold Valve (page 85)
.
Cleaning the Manifold Valve
1.
Position the valve stem so that it is in the closed
position (
g027562
Figure 115
1.
Valve open
2.
Valve closed
2.
Remove the 2 end-cap-fitting assemblies from
each end of the manifold body (
and
g028243
Figure 116
Agitation Valve Manifold
1.
Stem retainer
7.
Back seating O-ring (0.676
x 0.07 inch)
2.
Valve stem
8.
Valve-seat ring
3.
Stem port
9.
Manifold body
4.
Stem-capture retainer
10.
Ball valve
5.
End-cap fitting
11.
End-cap-fitting assembly
6.
End-cap seal O-ring
(0.796 x 0.139 inch)