g192607
Figure 45
1.
Section-bypass shutoff valve (closed position)
5.
For machines operated in the application-rate
mode, ensure that the section-bypass shutoff
valve is closed (
6.
Engage the parking brake and start the engine.
Note:
Allow the engine to warm for 10 minutes.
7.
For machines operated in the application-rate
mode, perform the steps in Using the Test
Speed; refer to the
Software Guide
for the
Multi Pro 5800-D and 5800-G turf sprayers with
ExcelaRate spray system.
Note:
Set the simulated test speed between 4
km/h (2 mph) and 14 km/h (9 mph).
Performing a Catch Test
1.
Set the spray section switch(es) to the O
N
position for the section(s) that you are testing.
2.
Set the throttle to the F
AST
position.
3.
Set the master section switch to the O
N
position.
4.
Perform a 15-second catch test at 1 of the active
spray nozzles.
g193177
Figure 46
5.
Shut off the master section switch, set the
throttle to the slow position, shut off the spray
pump, and shut off the engine.
6.
Set the graduated container on a level surface
and note the fluid volume (
Important:
When you are reading the
graduated container, you must set the
container on a level surface.
Important:
When you are reading the
graduated container, read the fluid volume in
the graduated container at the lowest point
of the fluid-surface curve.
Important:
Small errors reading the fluid
volume in the graduated container will
significantly impact the accuracy of the
sprayer calibration.
g193829
Figure 47
1.
Highest point of the
fluid-surface curve (
do not
measure here)
3.
Level surface
2.
Lowest point of the
fluid-surface curve
(
measure here
)
7.
Compare the volume of water in the graduated
container with the nozzle volume in the
15-second catch test table.
15-Second Catch Test Table
Nozzle Color
Milliliters
collected in 15
seconds
Ounces collected
in 15 seconds
Yellow
189
6.4
Red
378
12.8
Brown
473
16.0
Gray
567
19.2
White
757
25.6
38