g194665
Figure 36
Stop Engine Messages
When a stop engine message displays in the
InfoCenter, the operator should immediately park the
machine and shutoff the engine. Examples of the
advisory screens are as follows:
Important:
Continued operation of the engine
when a stop message displays will result in
damage to the engine.
1.
When the engine control unit (ECU) detects a
severe level fault, the
stop engine indicator
displays (
g194667
Figure 37
2.
Immediately park the machine and shutoff
the engine.
3.
An Active Fault message is next displayed
(
).
g194663
Figure 38
4.
Press button 1 through 5 to view the active fault
list ; refer to
in
.
•
Press button 1 or 2 to navigate up or down
the list.
•
Press button 3 to mute the audio alarm.
5.
Press button 5 to exit the active fault list and
return to the home screen; refer to
in
Engine Advisories Messages (page 33)
.
Operating the Sprayer
To operate the Multi Pro
®
Sprayer, first fill the sprayer
tank, apply the product mix to the job site, and finally
clean the tank and spray system. It is important that
you complete all 3 of these steps in succession to
avoid damaging the sprayer. For example, do not mix
and add chemicals in the sprayer tank at night and
then spray in the morning. This leads to separation of
the chemicals and possible damage to the sprayer
components.
CAUTION
Chemicals are hazardous and can cause
personal injury.
•
Read the directions on the chemical labels
before handling the chemicals and follow
all manufacturer recommendations and
precautions.
•
Keep chemicals away from your skin.
Should contact occur, wash the affected
area thoroughly with soap and clean water.
•
Wear appropriate personal protective
equipment (PPE) per the chemical
manufacturers instructions.
The Multi Pro
®
Sprayer is specifically designed for
high durability, provides the long sprayer life. Different
34