Page 6 -- 17
Electrical System
Starting Problems
Problem
Possible Causes
Starter solenoid clicks, but starter will not crank
(if solenoid clicks, problem is not in safety interlock
system).
Battery cables are loose or corroded.
Battery ground to frame is loose or corroded.
Battery is discharged or faulty.
Wiring at starter is loose or faulty.
Starter mounting bolts are loose or not supplying a
sufficient ground.
Starter solenoid is faulty.
Starter motor is faulty.
Nothing happens when start attempt is made.
Functional control lever is not in the NEUTRAL
position.
The parking brake is disengaged and the operator seat
is unoccupied.
Battery cables are loose or corroded.
Battery ground to frame is loose or corroded.
Battery is discharged or faulty.
Fuse(s) is (are) faulty.
The fusible link harness at the engine starter motor is
faulty.
Wiring to the start circuit components is loose,
corroded or damaged (see electrical schematic in
Chapter 10 -- Foldout Drawings).
The ignition switch or circuit wiring is faulty.
Starter solenoid or circuit wiring is faulty.
Main power relay or circuit wiring is faulty.
Fuse block is faulty.
Neutral switch is out of adjustment or is faulty.
TEC controller is faulty.
Electrical System
Summary of Contents for 04510 Greensmaster 3300 TriFlex
Page 2: ...Greensmaster 3300 3400 This page is intentionally blank ...
Page 4: ...Greensmaster 3300 3400 This page is intentionally blank ...
Page 6: ...Greensmaster 3300 3400 This page is intentionally blank ...
Page 24: ...Greensmaster 3300 Page 3 6 Gasoline Engine This page is intentionally blank ...
Page 38: ...Greensmaster 3400 Page 4 4 Diesel Engine This page is intentionally blank ...
Page 54: ...Greensmaster 3300 3400 Hydraulic System Page 5 2 This page is intentionally blank ...
Page 170: ...Greensmaster 3300 3400 Hydraulic System Page 5 118 This page is intentionally blank ...
Page 172: ...Greensmaster 3300 3400 Page 6 2 Electrical System This page is intentionally blank ...
Page 230: ...Greensmaster 3300 3400 Page 6 60 Electrical System This page is intentionally blank ...
Page 303: ...Greensmaster 3300 3400 Groomer Page 9 13 This page is intentionally blank Groomer ...
Page 318: ...Greensmaster 3300 3400 Page 10 2 Foldout Drawings This page is intentionally blank ...
Page 332: ...Page 10 16 This page is intentionally blank ...