![Toro 04510 Greensmaster 3300 TriFlex Service Manual Download Page 184](http://html.mh-extra.com/html/toro/04510-greensmaster-3300-triflex/04510-greensmaster-3300-triflex_service-manual_1132852184.webp)
Greensmaster 3300/3400
Page 6 -- 14
Electrical System
Diagnostic Display
TEC Controller Inputs
Diagnostic Display
LED Operation
JOYSTICK
LOWER
Joystick moved to lower (forward) position: LED ON
Joystick NOT moved to lower position: LED OFF
LEAK
DETECTOR (LD)
(Greensmaster 3300 machines only)
Leak detector switch closed (oil level is low): LED ON
Leak detector switch open (oil level is OK): LED OFF
ELECTRIC
REEL SPEED
Not used on Greensmaster 3300 or 3400 machines.
HYD OIL
TEMP (DSL)
(Optional for Greensmaster 3400
machines only)
Hydraulic temperature, temp switch and circuit wiring OK: LED ON
Hydraulic temperature, temp switch or circuit wiring faulty: LED OFF
COOLANT
TEMP (DSL)
(Greensmaster 3400 machines only)
Engine coolant temperature has exceeded 220
o
F (105
o
C): LED ON
Engine coolant temperature below 220
o
F (105
o
C): LED OFF
BACKLAP
Cutting reels in backlap position: LED ON
Cutting reels NOT in backlap position: LED OFF
PARKING
BRAKE (OFF)
Parking brake released: LED ON
Parking brake engaged: LED OFF
SEAT
SWITCH
Seat occupied: LED ON
Seat NOT occupied: LED OFF
JOYSTICK
RAISE
Joystick moved to raise (rear) position: LED ON
Joystick NOT moved to raise (rear) position: LED OFF
ALT FAULT
(DSL)
(Greensmaster 3400 machines only)
Engine not running OR alternator faulty: LED ON
Alternator OK: LED OFF
LOW ENGINE
OIL PRESSURE
Engine not running OR low engine oil pressure: LED ON
Engine oil pressure OK: LED OFF
NEUTRAL
SWITCH
Functional control lever in neutral position: LED ON
Functional control lever in mow or transport position: LED OFF
MOW
SWITCH
Functional control lever in mow position: LED ON
Functional control lever in neutral or transport position: LED OFF
KEY START
(NOTE: Place Functional Control Le-
ver in MOW or TRANSPORT so en-
gine will not start when turning ignition
switch to START)
Ignition switch in START position: LED ON
Ignition switch in RUN position: LED OFF
KEY
RUN
Ignition switch in RUN or START position: LED ON
NOTE:
When the ignition switch is in the OFF position,
all Diagnostic Display LED’s should be OFF.
NOTE:
The COOLANT TEMP (DSL) input can be simu-
lated by disconnecting the wire harness connector from
the temperature sender on the engine and then using a
jumper wire to connect the two (2) connector terminals.
The COOLANT TEMP (DSL) LED on the Diagnostic
Display should illuminate when the terminals are con-
nected and the ignition switch is in the ON position.
Summary of Contents for 04510 Greensmaster 3300 TriFlex
Page 2: ...Greensmaster 3300 3400 This page is intentionally blank ...
Page 4: ...Greensmaster 3300 3400 This page is intentionally blank ...
Page 6: ...Greensmaster 3300 3400 This page is intentionally blank ...
Page 24: ...Greensmaster 3300 Page 3 6 Gasoline Engine This page is intentionally blank ...
Page 38: ...Greensmaster 3400 Page 4 4 Diesel Engine This page is intentionally blank ...
Page 54: ...Greensmaster 3300 3400 Hydraulic System Page 5 2 This page is intentionally blank ...
Page 170: ...Greensmaster 3300 3400 Hydraulic System Page 5 118 This page is intentionally blank ...
Page 172: ...Greensmaster 3300 3400 Page 6 2 Electrical System This page is intentionally blank ...
Page 230: ...Greensmaster 3300 3400 Page 6 60 Electrical System This page is intentionally blank ...
Page 303: ...Greensmaster 3300 3400 Groomer Page 9 13 This page is intentionally blank Groomer ...
Page 318: ...Greensmaster 3300 3400 Page 10 2 Foldout Drawings This page is intentionally blank ...
Page 332: ...Page 10 16 This page is intentionally blank ...