or do the maintenance 

The  main  machine  is 
working 

but 

the 

monitor is not display 

1.

 

displaying  card  damaged,  or 

the  connection  with  the  main 
board is not good. 

Change it or reinsert it 

2.

 

monitor is brocken 

Invite 

the 

professionals to come 

3.

 

the  signal  cable  is  not 

properly inserted 

4.

 

 

Reinsert it. 

Communication fails 

1.

 

USB drive fails 

Reinstall it 

2.

 

bad  connection  on  USB  drive 
or line break 

Reinsert,  change  it  or 
check accordingly 

Printing  needle  refuse 
to  move,  the  printing 
indicator not light on 

1.

 

the  driving  cable  connection 
is not 

good, or line break, 

Check  the  line  or 
re-insert it 

2.

 

the 19 pin or 16 pin 

plug is not connect well.   

Check the line

 

3.

 

the control software 

is damaged. 

Re install it 

4.

 

failure  on  some  part  of  the 
control board. 

Change it or repire. 

The 

printing 

needle 

refused  to  move,,  but 
the indicator is on 

1.

 

driving  cable  contact  problem 
or line cut 

Check the line 

the 19 pin or 16 pin 

2.

 

plug is not connect well. 

Check the line 

3.

 

dive circuit damaged   

Check the circuit 

Needle  in  X  or  Y 
direction 

refuse 

to 

move 

1.

 

the  control  board  brocken  or 
bad connection. 

Change it or reinsert it 

2.

 

bad signal on the line of X or 
Y direction 

Check it   

3.

 

diving board brocken on X or 
Y direction 

Change it   

4.

 

motor  brocken  on  X  or  Y 
direction 

Change it 

Summary of Contents for HS-DP Series

Page 1: ...king on circle surface https youtu be Cp5vyfW7hFg list PLJswVwlJGu2TsU_GNHiKAh6 V2nVb5TOU software guide IF any question send email to us our email is info heatsign com Diagrams and graphs Basic infor...

Page 2: ...2 Air Power switch button Start Marking button Machine top view...

Page 3: ...3 Heavy load power connector warning this plug is strictly forbidden for hot plugging it will damage the machine...

Page 4: ...4...

Page 5: ...for air supply Printing pressure keep between 0 2 to 0 6 mpa Pneumatic pressure control valve push down to lock pull up and turn clockwise to increase pressure counter clockwise is to decrease pressur...

Page 6: ...ling box the other end to the computer USB exporting terminal This is controlling box Power switch button Power connect port Data transfer cable one end lead to the marker the other to the USB port of...

Page 7: ...7...

Page 8: ...8 Marking results...

Page 9: ...fix the machine on the bottom of the box just unscrew it See fig 1 Fig 1 2 during the transport the height adjusting wheel is dismounted from the machine head install it when it arrived at the site fi...

Page 10: ...10 fig4 There are 4 screws to fix the control box fig5 Way of fastening Fixing the control box when it arrives on site When it arrives positioning chuck clamp can be fixed a bit backward...

Page 11: ...11 How to transfer Chinese to English When you need use rotary chuck click on this button then Y axis will turn to rotary axis...

Page 12: ...12 How to lead your deign file often plt format to the software First open the software and choose add mark...

Page 13: ...13 Second choose the Graph Third click the below area after clicking Graph Fourth click the Browse...

Page 14: ...fer to our software instruction manual as followings Software Manual A Install of the software Installation environment WIN 98 WIN XP VISTA Software installation insert the disk into the CD ROM or ins...

Page 15: ...ick the desktop ThorX6 icon switch on the controller power before you open the software ThorX6 industrial engraving marking Control System ThorX6 is beginning wait a few seconds to complete the system...

Page 16: ...ameters will be also different now Mark function panel displays is the text type mark s parameters which we just create these parameters include the maker s location content fonts etc So far the text...

Page 17: ...f the software every time you change the mark s location marking needle will automatically move to the new marker location There is another more efficient way to change the mark s position click the m...

Page 18: ...g chapters b c 2 2 Operation of the file Click the main file operation button of the ThorX6 the menu of the document will pop up as the following fig d Establish a new file create a new file if an und...

Page 19: ...t will display several recently used files click one of them it will be able to quickly open a file 2 3 Create and editing of a mark 2 3 1 Create a text mark Then content of a text mark could be compo...

Page 20: ...height of the tag engraving c Angle this is a designated angle that rotates around the X and Y axis to the fan shaped text this angle means the start and ending angle of the arrangement of the fan sha...

Page 21: ...of a change after each of the engraving b Serial number Normally the serial number formed by a serial numbers or at least the end of the content is a numerical character if it is not the content will...

Page 22: ...ntent tag will be to change the ground format the date specified time code Format is a special code formed by a group of characters which determines the character formatting tag content Formatting cha...

Page 23: ...grid i Number of decimal places if the value contains a decimal ruler then the values of the number of decimal places j Fan shaped radius If the fan shaped radius set to a valid value not 0 you can c...

Page 24: ...rding of determining the marking position except the method of using direction key and the mouse that intruduced in the chapter of view operation there are another Alignment feature available in ThorX...

Page 25: ...the needle alignment feature sub menu needle alignment feature has a variety of ways as follows a The lower left corner aiming the marking needel at the lower left corner of the mark b The lower right...

Page 26: ...ton marking control software will automatically start from the top to bottom left to right to reordering it which is the most commonly used sorting method 2 6 2 Set Marking Marking speed refers to the...

Page 27: ...re gas source let the marking needle stop for a short period of time so that you can effectively avoid smearing This is a shor t pause of the time we referred to as smearing this waiting time we calle...

Page 28: ...n appointed timing to autmatic engraving the marks Reset to reset the engraving needle to the original machnical point 2 4 4 Isotype number comparision during the engraving The control software of the...

Page 29: ...ep length motor gear diameter 360 drive motor step breakdown of the number of terms In most cases we use most of the motor gear diameter of 14 23 the electrical step angle of 1 8 the drive segment num...

Page 30: ...of cleaning the dust is switch off the power of the controller open the external machine box clean them with pressured gas to blow on it Pay attention to clean the dust around the machine all the tim...

Page 31: ...tion is not good or line break Check the line or re insert it 2 the 19 pin or 16 pin plug is not connect well Check the line 3 the control software is damaged Re install it 4 failure on some part of t...

Page 32: ...good Check the line The printing needle striks none stopping or the strike force is small 1 lack of air flux Change the big air tube 2 the air switch not opened enough Open it bigger 3 the spring is s...

Page 33: ...out and the gap is big Adjust it 4 contorl program is damaged Reinstall it The hardware could not get in A mistakenly configuration of hardware in CMOS Modify the configuration of the CMOS Note Due de...

Reviews: