6-6
Tolomatic User Guide:
ICR Rod Style Integrated Control Actuator
6 :
H O W T O U S E T H E I C R / I C M S V 1 P P L U S A C T U A T O R
6.7 ICR/ICM SV1P Plus Amplifier Files
6.7.1 Loading the Amplifier Files
The amplifier file (*.ccx) for the ICR/ICM SV1P Plus actuator is configured and
loaded by Tolomatic at the factory. The amplifier file contains setup, motor, and
tuning information allowing the actuator to operate once it is powered. The default
mode of operation is in a position mode via a program. Input 1 is predefined as
enable. Input 11 (internal) is the motor temperature switch. Digital output #4
is
predefined as the brake output.
If the actuator becomes inoperable for any reason, it can be returned to factory
defaults by copying the amplifier data. Follow steps 1 though 5 in the procedure
outlined in
CME 2
®
User Guide, Appendix A: Copy Amplifier Data,
then load the
“ICRSVIP.ccx” file provided with the ICR/ICM SV1P Plus.
IN1 = Enable
IN11 = Motor Temp Switch
6.7.2 Saving Amplifier Files
If any changes to setup, motor, or tuning have been made, a new amplifier can be
saved to the disk with the following procedure:
Click on the ‘Save amplifier data to disk’ icon on the tool bar.
Figure 6-7: CME 2
®
Save Amplifier Data To Disk Icon
CMe 2
®
User Interface Tool Bar Icons and Functions (con’t)
Amplifier Properties Icon
Displays basic amplifier properties.
Save Amplifier Data to Disk Icon Saves contents of amplifier RAM to a disk file.
Restore Amplifier Data From
Disk
Restores an amplifier file from disk to amplifier
RAM.
Save Amplifier Data to Flash
Saves contents of amplifier RAM to flash memory.
Restore Amplifier Data from
Flash
Restores contents of flash memory to amplifier
RAM.
For complete details on the File, Amplifier, Tools and help menu choices and
functional diagram, refer to the CME 2
®
User Guide furnished on the CD-ROM that
shipped with the ICR Plus actuator.