N-CC1000/CC1110/VT1010 INSTRUCTION MANUAL (Applications)
3-27
CHAPTER 3. Performing Settings with Internet Explorer
Send-To Address
Enter the email address of the receiver to which the alarm email is to be transmitted.
Reply-To Address
Enter the reply address the alarm email is to be returned to.
Note: The From address is fixed at [email protected]. Setting the Reply-To address enables the
receiver to transmit email replies to that address.
3.8.3. Alarm Output
Perform settings for contact output switching operations.
Relay
Select either a make contact or a break contact.
Auto Release
Perform settings for automatic alarm output reset. Select Off to maintain output while an alarm is activated,
and Time (0.5, 1, 2, 5, 10, or 60 seconds) to automatically reset the output after a predetermined period of
time elapses.
Source
Select events that activate the alarm output.
None: Alarm output is not activated in the event of a received alarm trigger.
Connection: Activation by way of set connections.
Alarm Input: Activation by alarm input.
Remote Alarm Input: Activation by remote contact input.
Video Loss: Activation by video loss alarm.
Test
Click "Test" to manually activate and check the alarm output for correct operation.