Page 32
Installation, use and maintenance guide
Mon Amour
present and operating (for the classification see UNI 10642 and UNI 719). The connection between the appliance and
the flue outlet must only receive exhaust from one heat generator.
The installer must provide one or more access points on the flue outlet to check the emissions once the appliance has
been installed; these access points must be made in such a way as to be air-tight sealable to prevent exhaust gas
leaks.
The appliance is equipped with a smoke exhaust motor, it works in low pressure and with very low smoke temperatures,
consequently it is recommended to insulate it and to ensure that the flue outlet is sized appropriately in order to avoid
the possible risk of creating condensation.
10.3.1 FLUE OUTLET / FLUE SYSTEM COMPONENTS
Every chimney must have minimum number of components as laid down by standard UNI EN 10683 which are also indicated in the
figure below:
CAUTION: Wall outlets, that is outlets installed on the outer front wall without the use of a chimney/flue outlet /flue pipe
to convey the combustion products to the roof, are strictly prohibited.
Components and accessories of a
chimney
Key
1 Chimney
2 Flow path
3 Smoke discharge tube
4 Thermal insulation
5 External wall
6 Outer lining
7 Flue outlet section
8 Multi wall chimney
9 Connector
10 Flue pipe
11 Heat generator