background image

P

Preparation manual

Smart Bell 65/55 MF

Serial number:

Production date:

Summary of Contents for Smart Bell 65/55 MF

Page 1: ...P Preparation manual Smart Bell 65 55 MF Serial number Production date ...

Page 2: ... without the prior written permission of Barbas Bellfires BV This document could contain technical inaccuracies or typographical errors Barbas Bellfires BV reserves the right to revise this document from time to time in the contents thereof Contact information Barbas Bellfires BV Hallenstraat 17 5531 AB Bladel The Netherlands Phone 31 49 733 9200 E mail info bellfires com Introduction 2 Smart Bell...

Page 3: ...l specification 17 5 1 Dimensions Smart Bell 65 55 with a Built in frame 17 5 2 Dimensions Smart Bell 65 55 with a Classic frame 35 mm 18 5 3 Dimensions Smart Bell 65 55 with a Classic frame 52 mm 19 5 4 Dimensions Smart Bell 65 55 with a Classic frame 70 mm 20 5 5 Dimensions Smart Bell 65 55 with an Insert frame 15 mm 21 5 6 Dimensions Smart Bell 65 55 with an Insert frame 50 mm 22 5 7 Dimensions...

Page 4: ...a typical setup The illustrations are for instructional use only 1 1 How to work with this document 1 Make yourself familiar with the structure and content of the document 2 Read the safety chapter in detail 3 Make sure that you understand all the instructions 4 Do the procedures completely and in the given sequence 1 2 Warnings and cautions used in this document Warning If you do not obey these i...

Page 5: ...ipe The in ner pipe is used as flue gas channel and the space be tween the inner pipe and the outer pipe is used as combustion air channel Flue gas channel The flue gases from the appliance flow through the channel to the outlet by a natural draft Combustion air channel Supplies the appliance with fresh air from the outlet through the channel Outlet terminal Entry for the combustion air channel an...

Page 6: ... specified in this manual and the related documents Only use the following brands for the installation of the concentric flue system Manufacturer system Bellfires Muelink Grol system Poujoulat DUOGAS system Ontop Metaloterm US system Jeremias STB STB Schoorsteen Techniek Brummen NL H Twin system Jeremias TWIN GAS system Do not use a combination of parts from different brands for the installation o...

Page 7: ... is made of flammable material take correct safety measures Install a temperature protection plate made of nonflammable material between the appliance and the floor The appliance must be installed into an existing open fireplace or as a built in appliance in a new fireplace If the concentric flue system is installed in a chimney that is used for wood or coal fire clean the chimney If you built a n...

Page 8: ...l directives for the exact minimum distances If the outlet is installed horizontally in less than 0 5 m and vertically in less than 2 m from a public area install an effective protector Make sure that the mesh size of the guard does not affect the operation of the appliance If the height of the outlet is less than 3 meter from the floor the distance between the outlet and a garden or a terrace mus...

Page 9: ...g Make sure that the casing is made of heat resistant material Make sure that air can flow in the casing Use grates near the floor and near the ceiling Do this for every floor where the casing is located Do not insulate the concentric flue The parts that are required for the installation of the concentric flue system are numbered in the illustrations and refer to the part list in 6 Use the univers...

Page 10: ...h a roof outlet Rigid concentric flue systems 4 28 100 1 10 11 12 13 23 24 17 16 24 18 16 Y Y min max Flue gas restriction plate width Concentric connection on the appliance is Ø100 Ø150 mm 2 0 4 0 m 30 mm 4 0 12 0 m 40 mm Requirements 10 Smart Bell 65 55 ...

Page 11: ...Y2 Y1 min max X min max Y1 Y2 min max Flue gas restriction plate width Concentric connection on the appliance is Ø100 Ø150 mm 1 0 11 0 m 0 3 0 m 1 0 11 0 m Caution Make sure that Y1 Y2 is at least 2 times larger than X Requirements Smart Bell 65 55 11 ...

Page 12: ... 29 23 25 18 10 11 12 13 Y Y min max Flue gas restriction plate width Concentric connection on the appliance is Ø100 Ø150 mm 2 0 4 0 m 30 mm 4 0 12 0 m 40 mm Roof outlet using an flexible Ø100 mm liner in an existing lined chimney Requirements 12 Smart Bell 65 55 ...

Page 13: ...min max Flue gas restriction plate width Concentric connection on the appliance is Ø100 Ø150 mm 1 0 11 0 m 0 3 0 m 1 0 11 0 m Caution Make sure that Y1 Y2 Y3 is at least 2 times larger than X Roof outlet using an flexible Ø100 mm liner in an existing lined chimney Requirements Smart Bell 65 55 13 ...

Page 14: ... Flue gas restriction plate width Concentric connection on the appliance is Ø100 Ø150 mm 2 0 4 0 m 30 mm 4 0 12 0 m 40 mm Roof outlet using an flexible Ø100 mm liner and flexible Ø150 mm liner in an existing unsound lined chimney Requirements 14 Smart Bell 65 55 ...

Page 15: ...estriction plate width Concentric connection on the appliance is Ø100 Ø150 mm 1 0 11 0 m 0 3 0 m 1 0 11 0 m Caution Make sure that Y1 Y2 Y3 is at least 2 times larger than X Roof outlet using an flexible Ø100 mm liner and flexible Ø150 mm liner in an existing unsound lined chimney Requirements Smart Bell 65 55 15 ...

Page 16: ...figure The centre of the inner pipe must be positioned above the centre of the outer pipe Rigid concentric flue systems 19 1 10 11 12 13 4 28 100 14 Y 0 16 m X Y min max X min max Flue gas restriction plate width Concentric connection on the appliance is Ø100 Ø150 mm 1 0 2 0 m 0 4 0 m 2 0 5 0 m 0 8 5 m Requirements 16 Smart Bell 65 55 ...

Page 17: ...5 5 Technical specification 5 1 Dimensions Smart Bell 65 55 with a Built in frame Technical specification Smart Bell 65 55 17 ...

Page 18: ...5 5 2 Dimensions Smart Bell 65 55 with a Classic frame 35 mm Technical specification 18 Smart Bell 65 55 ...

Page 19: ...5 5 3 Dimensions Smart Bell 65 55 with a Classic frame 52 mm Technical specification Smart Bell 65 55 19 ...

Page 20: ...5 5 4 Dimensions Smart Bell 65 55 with a Classic frame 70 mm Technical specification 20 Smart Bell 65 55 ...

Page 21: ...5 5 5 Dimensions Smart Bell 65 55 with an Insert frame 15 mm Technical specification Smart Bell 65 55 21 ...

Page 22: ...5 5 6 Dimensions Smart Bell 65 55 with an Insert frame 50 mm Technical specification 22 Smart Bell 65 55 ...

Page 23: ...Insert frame 50 mm and Convection fan 5 8 Dimensions of the restriction plate Width of the delivered flue restriction plates in mm Concentric flue connection Ø100 Ø150 Roof mounted outlet 30 40 50 65 Technical specification Smart Bell 65 55 23 ...

Page 24: ...pter The guarantee on the appliance lapses if it is installed fully or partially with other components or a different flue system The concentric flue Ø100 mm Ø150 mm systems can be used with either a newly built or existing chimney Make sure that the wall or roof termination kit that is used for the installation of the concentric flue system is also listed in the available parts list 6 1 Appliance...

Page 25: ... Twin wall balanced flue pipe L 500 mm 11 302290 Twin wall balanced flue pipe L 1000 mm 12 302291 Telescopic twin wall balanced flue pipe L min 325 max 440 mm 13 302292 Adjustable length twin wall balanced flue pipe L 500 mm 14 302297 Twin wall balanced flue el bow 90 Available components for the concentric flue system Smart Bell 65 55 25 ...

Page 26: ...h 20 45 with lead flashing 18 302213 Roof flashing for existing chimney or flat roof 19 302296 Horizontal wall termination kit L 600 mm adjustable including a set of wall spacer plates 20 302293 Stainless steel locking band Ø150 mm quick fastening 21 302210 Silicone seal Ø150 mm 23 302215 Wall strap 24 302214 Set of ceiling finishing plates Fire stops Available components for the concentric flue syste...

Page 27: ...279 Stainless steel adapter piece 150 fire to fl exible Ø148 mm external rigid x Ø148 mm internal flex appliance Ø150 mm flex 28 302217 Stainless steel locking band Ø150 mm For adapter 150 appliance Ø150 mm flex Screw fastening 29 303776 Stainless steel screws Ø3 5 mm x 9 5 mm For securing the flexible concentric flue Minimum 3 screws per con nection 30 304041 Hose clamp Ø100 mm Mini mum 2 per connection...

Page 28: ...centric bend with in spection panel 36 321948 Universal wall floor support Ø150 mm Color rvs Stainless steel self color polished antr Anthacite color lacquer matt Adjustable roof flashing for a slope 45 can be supplied on request When installing a balanced flue closed gas fire in an existing chimney ensure stainless steel flexible liners Ø100 mm or Ø130 mm conforming with BS 316 are used to conduct...

Page 29: ...lanced flue pipe L 450 mm 11 37100405 Twin wall balanced flue pipe L 950 mm 12 37100429 Telescopic twin wall balanced flue pipe L min 390 max 640 mm 14 37100441 Twin wall balanced flue el bow 90 15 37100421 Twin wall balanced flue el bow 45 37100411 Twin wall balanced flue el bow 30 37100401 Twin wall balanced flue el bow 15 Available components for the concentric flue system Smart Bell 65 55 29 ...

Page 30: ... roof pitch of 15 30 17 45150172 Roof flashing suitable for a brick roof with a roof pitch of 30 45 17 45150173 Roof flashing suitable for a tiled roof with a roof pitch of 30 45 18 45150169 Roof flashing for existing chimney or flat roof 19 37100610 Horizontal wall termination kit L min 365 mm max 585 mm 20 45150076 Stainless steel locking band Ø150 mm quick fastening 23 45150072 Wall strap Ø150 mm A...

Page 31: ...428 Set of ceiling finishing plates Fire stops suitable for a roof pitch of 40 50 34 37100407 Concentric pipe with inspec tion opening L 250 mm 36 45150165 Roof support universal Ø150 mm 36 45150081 Floor support universal Ø150 mm 37 37100611 Adapter Bellfires Ø100 150 mm Poujoulat DUOGAS Ø100 150 mm Appliance 100 150 Poujoulat DUO GAS 100 150 100 37100614 Adapter Bellfi res Ø130 200 mm Poujoulat DUO...

Page 32: ... wall balanced flue pipe L 250 mm 10 US 50 10 Twin wall balanced flue pipe L 500 mm 11 US 100 10 Twin wall balanced flue pipe L 1000 mm 12 USPP 10 Telescopic twin wall balanced flue pipe L min 60 max 250 mm 14 USB 90 10 Twin wall balanced flue el bow 90 15 USB 45 10 Twin wall balanced flue el bow 45 15 USB 30 10 Twin wall balanced flue el bow 30 Available components for the concentric flue system 32 Sm...

Page 33: ... 10 Adjustable roof flashing Roof pitch 20 45 with lead flashing 17 USDH 10 Roof flashing plate for roof pitch 5 30 18 USDP 10 Roof flashing for existing chimney or flat roof 18 USDPAL 10 Roof flashing Aluminium For existing chimney or flat roof 19 USDHC5 10 Horizontal wall termination kit L 475 mm adjustable 20 USKB 10 Locking band quick fasten ing Available components for the concentric flue system Sma...

Page 34: ... USMB 10 Wall strap adjustable 23 USEB 10 Fitting bracket 24 USCP 10 Set of ceiling finishing plates Fire stops Centring plates 24 USDQ 10 Roof support 25 USSAN 10 Renovation set 25 USSAN1 10 Top of renovation set 25 USSAN2 10 Bottom renovation set Available components for the concentric flue system 34 Smart Bell 65 55 ...

Page 35: ...n panel L 250 mm 34 USEM 10 Concentric pipe with gauging orifice L 150 mm 35 USBI 10 90 concentric bend with in spection panel USR 10 Rosette smooth Ø150 mm USMPG 10 Wall plate large Ø150 mm square 300 mm USAH 10 Spacer bracket USVG 10 13 Concentric reduction of Ø100 Ø150 mm Ø130 Ø200 mm Available components for the concentric flue system Smart Bell 65 55 35 ...

Page 36: ...00 mm 10 ATWINL 15 100 150 Twin wall balanced flue pipe L 250 mm 12 H TWIN 742 100 150 Telescopic twin wall balanced flue pipe L min 1100 max 1400 mm 12 H TWIN 467 100 150 Telescopic twin wall balanced flue pipe L min 1100 max 1900 mm 12 ATWIN 197 100 150 Telescopic twin wall balanced flue pipe L min 600 max 900 mm 15 ATWIN 16 100 150 Twin wall balanced flue el bow 15 Available components for the conc...

Page 37: ...18 100 150 Twin wall balanced flue el bow 45 14 ATWIN 60 100 150 Twin wall balanced flue el bow 90 14 ATWIN 60F 100 150 Twin wall balanced flue el bow 90 Short Especially for connection to a wall termi nation 16 A 463 100 150 Roof termination long with pipe L 1080 mm Vertical Available components for the concentric flue system Smart Bell 65 55 37 ...

Page 38: ...of flashing for roof pitch 30 with lead flashing and storm collar 17 ATWIN 60DD 100 150 Roof flashing for roof pitch 45 with lead flashing and storm collar ATWIN 307 100 150 Storm collar 24 ADBL DW 100 150 Set of ceiling finishing plates Fire stops 20 ATWIN 45 100 150 Locking band Screw fasten ing Standard on all compo nents 23 ATWIN 22 100 150 Wall strap adjustable 23 ATWIN 23 100 150 Wall strap dista...

Page 39: ...spection panel with cover cap and condensation opening ATWIN 465 100 150 Adapter H TWIN Ø100 150 Flex Stainless steel Ø100 mm Incl Ceiling plate 300x300 mm ATWIN 466 100 150 Adapter Flex Stainless steel Ø100 mm H TWIN Ø100 150 Incl Chimney ceil ing plate 300x300 mm 36 ASDH2 100 150 Universal wall floor support Ø150 mm 100 A464 130 Concentric reduction of H TWIN Ø130 Ø200 mm H TWIN Ø100 Ø150 mm Avai...

Page 40: ...uding locking band 2x 11 TWG13 100 150 Twin wall balanced flue pipe L 1000 mm Including lock ing band 10 TWG14 100 150 Twin wall balanced flue pipe L 500 mm Including locking band 10 TWG15 100 150 Twin wall balanced flue pipe L 250 mm Including locking band TWG1801 100 150 Twin wall balanced flue pipe L 1000 mm with 4 spacer brackets on the outside In cluding locking band Available components for the ...

Page 41: ...0 Including locking band 15 TWG18 100 150 Twin wall balanced flue el bow 45 Including locking band 14 TWG60 100 150 Twin wall balanced flue el bow 90 Including locking band 14 TWG1786 100 150 Twin wall balanced flue el bow 90 with support leg In cluding locking band and sealing cap under 14 TWG1676 100 150 Twin wall balanced flue el bow 90 short eccentric Especially for connection to a wall terminatio...

Page 42: ...lu flashing and storm collar 17 TW38 150 Roof flashing with a roof pitch of 26 35 With flex alu flashing and storm collar 17 TW54 150 Roof flashing with a roof pitch of 36 45 With flex alu flashing and storm collar 18 TW52 150 Roof flashing for existing chimney or flat roof With storm collar KL72 150 Storm collar spare part 19 TWG1619 100 150 Wall termination kit L 600 mm horizontal Adjustable Incl locking...

Page 43: ... mm ZU WA891200 Extension pieces for the wall strap ZUWA704 L 200 mm ZU WA891250 Extension pieces for the wall strap ZUWA704 L 250 mm ZUWA706 Extension pieces for the wall strap ZUWA704 L 400 mm WA 50 360 mm 24 ZUDA074 150 Set of ceiling finishing plates Fire stops for a flat roof 0 24 ZUDA99V 150 Set of ceiling finishing plates Fire stops for a pitched roof 0 30 24 ZUDA98V 150 Set of ceiling finishin...

Page 44: ...of ceiling plate with adapter FLEX to TWIN GAS 25 ZUWA1618 100 Adapter TWIN GAS to Schaft DE 25 TWG1732 100 150 Chimney flat roof ceiling plate with adapter Ø100 rig id flex to TWIN GAS 33 TWG317 100 150 Concentric T piece 90 In cluding locking band 34 TWG51 100 150 Concentric pipe with gauging orifice L 200 mm Including locking band 35 TWG10 100 150 Concentric pipe L 300 mm with cleaning opening ins...

Page 45: ... with transverse support Type II 500 mm Distance to wall WA 50 150 mm DW393 Wall support with transverse support Type III 750 mm Distance to wall WA 150 250 mm DW407 Wall support with transverse support Type IV 1030 mm Distance to wall WA 250 360 mm 17 24 LUX ECO 150 Insulation roof flashing L Max 500 mm adjustable Wall thickness LUX ECO In sulation min 25 mm 19 LUX ECO 150 Insulation wall flashing ...

Page 46: ...Available components for the concentric flue system 4 46 Smart Bell 65 55 ...

Page 47: ...Available components for the concentric flue system Smart Bell 65 55 4 47 ...

Page 48: ...Y Your Bellfires dealer 001 10 04 2018 347185 ...

Reviews: