background image

PCBM-42 GAS CONVERSION KIT, MILLIVOLT, NATURAL GAS TO PROPANE/LP GAS

[FOR USE WITH APPLIANCE MODELS MISSION42, BRT4042, BRT4342, BRT4542]

PCBM-42 GAS CONVERSION KIT

NATURAL GAS TO PROPANE/LP GAS

P/N 127197-01
Rev. C, 03/2017

HEARTH PRODUCTS

KITS AND ACCESSORIES

Cat. No.

Model

Description

F1126

PCBM-42 Gas Conversion NG to LP

KIT CONTENTS

1 ea. Pilot Orifi ce LP (#30)
1 ea. Main Burner Orifi ce (#50)
1 ea. Air-Mixer Brass LP
1 ea. Gas Valve Regulator LP
1 ea. Conversion Label, English
1 ea. Conversion Label, French
1 ea. Conversion Information Label
1 ea. Instruction Sheet

REQUIRED TOOLS AND SUPPLIES

7/8” Open End Wrench or Adjustable Wrench
3/4” Open End Wrench or Adjustable Wrench
3/8” Deep Socket Drive
Torx T20 or Slotted Screwdriver
5/32” Allen Wrench
#2 Short Phillips Screwdriver
Thread Sealant (Resistant to Propane/LP)

TURN OFF THE GAS SUPPLY TO THE APPLIANCE. DISCONNECT 
ELECTRICAL POWER SUPPLY. 

READ ALL THE STEPS BEFORE STARTING THE CONVERSION. IN-
STALLER NOTICE: THESE INSTRUCTIONS MUST BE LEFT WITH THE 
APPLIANCE.

When installing gas components use pipe joint compound or 
Tefl on tape on all pipe fi ttings before installing (Do not use pipe 
joint compounds on fl are fi ttings).

THE APPLIANCE MUST BE OFF AND COLD BEFORE PERFORMING 
THE GAS CONVERSION.

ALL WARNINGS, PRECAUTIONS AND INSTRUCTIONS IN THE INSTAL-
LATION AND OPERATION MANUAL PROVIDED WITH THE APPLIANCE 
APPLY TO THESE INSTRUCTIONS.

GENERAL INFORMATION

Gas conversion kits are available to adapt the appliance from the 
use of one type of gas to the use of another. These kits contain all 
the necessary components needed to complete the task including 
labeling that must be affi xed to ensure safe operation.

       

WARNING

This conversion kit shall be installed by a qualifi ed 
service agency in accordance with the manufac-
turer's instructions and all applicable codes and 
requirements of the authority having jurisdiction.  If 
the information in these instructions is not followed 
exactly, a fi re, explosion or production of carbon 
monoxide may result causing property damage, 
personal injury or loss of life.  The qualifi ed service 
agency performing this installation is responsible 
for the proper installation of this kit and assumes 
responsibility for this conversion. The installation 
is not proper and complete until the operation of the 
converted appliance is checked as specifi ed in the 
manufacturers instructions supplied with the kit. 

 IMPORTANT LE CANADA SEULEMENT

La conversion devra être effectuée conformément aux 
recommandations des autorités provinciales ayant 
juridiction et conformément aux exigences du code 
d'installation CAN/CSA B149.1.

         IMPORTANT CANADA

The conversion shall be carried out in accordance with 
the requirements of the provincial authorities having 
jurisdiction and in accordance with the requirements 
of the CAN/CSA B149.1 Installation code.

            

AVERTISSEMENT

Cet équipement de conversion sera installé par 
une agence qualifi ée de service conformément aux 
instructions du fabricant et toutes exigences et codes 
applicables de l'autorisés avoir la juridiction.  Si 
l'information dans cette instruction n'est pas suivie 
exactement, un feu, explosion ou production de 
protoxyde de carbone peut résulter le dommages 
causer de propriété, perte ou blessure personnelle de 
vie.  L'agence qualifi ée de service est esponsable de 
l'installation propre de cet équipment.  L'installation 
n'est pas propre et compléte jusqu'à l'opération de 
l'appareil converti est chéque suivant les critères 
établis dans les instructions de propriétaire provi-
sionnées avec l'équipement.

1

f i r e - p a r t s . c o m

Summary of Contents for PCBM-42

Page 1: ...ING This conversion kit shall be installed by a qualified service agency in accordance with the manufac turer s instructions and all applicable codes and requirements of the authority having jurisdiction If the information in these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified ...

Page 2: ...e installer and adhered to the appliance at the time of the conversion Contact your local gas supplier for deration requirements for your area CAUTION The gas supply shall be shut OFF prior to discon necting the electrical power before proceeding with the conversion ATTENTION Avant d effecteur la conversion coupez d abord l alimentationengaz ensuite coupezl alimentation electrique Figure 1 Removin...

Page 3: ...itting to prevent turning burner tube 9 Retighten flare fitting on flexible manifold tube with the 3 4 open end wrench and 7 8 back up wrench 10 Reattach pilot shield onto burner bracket with screw removed in step 1 3 8 Deep Socket Propane LP Gas Orifice Propane LP Gas Air Mixer Fitting 3 8 Flare Fitting Natural Gas Orifice Fitting Burner Bracket Flange Burner Tube 7 8 Back Up Wrench Pilot Burner ...

Page 4: ...e 9 Figure 9 Conversion Information Label CONVERSION INFORMATION LABEL This appliance was converted on ___ ___ ___ to ______________ gas with Kit No _______________________ by _____________________________ _____________________________ _____________________________ name and address of organization making this conversion which accepts the responsibility that this conversion has been properly made 1...

Page 5: ... appliance owner s manual WARNING Test all gas piping and connections for leaks after installation or servicing Correct leaks at once WARNING Never use an open flame to check for a leak Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once Figure 11 Inspect for Proper Burner Flame Appearance No Blue Flame Center Soot at Flame Tip Dark Orange Fl...

Page 6: ...___________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________________________________________________...

Page 7: ...___________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________________________________________________...

Page 8: ...P reserves the right to make changes at any time without notice in design materials specifica tions prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1508 Elm Hill Pike Suite 108 Nashville TN 37210 fire parts com ...

Reviews: