Page 10
Installation, use and maintenance guide
Mon Amour
9
7
2
418
9
6
8
426
8
2
4
1
418
487
4
8
7
O
80
2 – TECHNICAL CHARACTERISTICS*
* All the data are based on the appliance fuelled
with EN 14961 standard type-approved pellets.
** Important: take into consideration the fact
that the heatable volume is greatly influenced
by the insulation of the house, i.e. the energy
class of the building and by the position of the
appliance in the planimetry of the house. The
indicated
values,
therefore,
can
vary
considerably.
MON AMOUR
Height (mm)
972
Depth (mm)
487
Width (mm)
418
Weight (Kg)
99
Firebox power Min. / Max. (KW)
3.15 / 7.69
Rated power Min. / Max. (KW)
2.82 / 6.74
Min/Max consumption (Kg/h)
0.65 / 1.59
Ø smoke exhaust pipe (mm)
80
Min. draught at rated power (Pa)
10
Min. draught at reduced power (Pa)
10
Tank capacity (Kg)
15
Average smoke temperature at rated power (°C)
178
Average smoke temperature at reduced power (°C)
98.2
Smoke flow at rated power (g/s)
6.0
Smoke flow at reduced power (g/s)
4.3
Efficiency at rated power (%)
87.63
Efficiency at reduced power (%)
89.46
CO concentration with 13% O2 at rated power (mg/m3)
106.8
CO concentration with 13% O2 at reduced power (mg/m3)
553.2
Power supply voltage and frequency
230V 50Hz
Max electrical consumption
1.18 - 271W
Min electrical consumption
0.29A - 66W
Heatable volume (m3)
189**