I
Page 23
installation, use and maintenance guide
Mon Amour
MANUALprogram
In the MANUAL program the room temperature thermostat of the radio control is disabled. It will therefore be possible to manually set
both the ventilation power and the combustion power.
-
To set or change the combustion power simply press the Flame Button (1), and the flame symbol on the screen will begin to
flash for several seconds. While it is flashing press the Down arrow (3) to reduce the combustion power, and on the display you
will see the bars disappear in sequence; vice versa to increase the combustion power, press the Up arrow (4).
The combustion level changes with each press of DOWN key (3) and UP key (4) .
-
To set or modify the ventilation power simply press the Ventilation button (2), and the fan symbol will begin to flash for a few
seconds. While it is flashing press the Down arrow (3) to reduce the ventilation power, and on the display you will see the bars
disappear in sequence; vice versa to increase the ventilation power, press the Up arrow (4).
The ventilation power changes with each press of DOWN key (3) and UP key (4).
CAUTION : It is possible that, due to radio interference or sending commands too close together, the changes will not
be implemented. With this program you can also use the infrared control supplied. It is normal that in the manual cycle
the ventilation is often set at the maximum speed in order to cool the appliance body more effectively.
AUTO 5 program
In program AUTO 5 the room temperature thermostat is enabled. The remote control adjusts the ventilation and combustion power
automatically in relation to the target room temperature set in radio control display.
You can vary the desired room temperature by simply pressing DOWN key (3) and/or UP key (4).
The remote control will set the maximum combustion and ventilation power and modulate them both as the room temperature (5R)
approaches the preset target temperature.
Once the target temperature has been achieved the combustion power and the ventilation power will remain steady at the minimum
value.
Caution: it is possible that, due to radio interference, the commands sent to the generator will not be implemented.
When using this program the infrared remote control supplied cannot be used.
Attention: the power and the ventilation depend on the preset target temperature, if the required temperature is too high
or not reachable the appliance could operate at maximum power for long periods of time.
AUTO 3 program
In program AUTO 3 the room temperature thermostat is enabled. The remote control adjusts the ventilation and combustion power
automatically in relation to the target room temperature set in radio control display.
You can vary the desired room temperature by simply pressing DOWN key (3) and/or UP key (4).
The radio control will remain steady at the maximum value, level 3 for the combustion power and level 4 for the ventilation power,
and lower the level as the room temperature approaches the preset target temperature.
Once the target temperature has been achieved the combustion power and the ventilation power will remain steady at the minimum
value.
Caution: it is possible that, due to radio interference, the commands sent to the appliance will not be implemented.
When using this program the infrared remote control supplied cannot be used. Caution: the power and the ventilation
depend on the preset value, if the required temperature is too high or not reachable the appliance could operate at
maximum power for long periods of time.
ECONOMY program
In the ECONOMY program the appliance always operates at the minimum combustion power and the minimum ventilation power.
When using this program the infrared remote control supplied cannot be used.
ATTENTION: THE THERMOCOMFORT RADIO CONTROL DOES NOT SWITCH THE APPLIANCE ON OR OFF.
THE APPLIANCE MUST ALWAYS BE STARTED UP AND SHUT DOWN FROM THE CONTROL PANEL OR
THROUGH PROGRAMMING.
Keep in mind that radio wave transmissions can be affected by the surrounding environment: the presence of thick walls can reduce
the transmission that normally extends to 6-7 metres.
ATTENTION: to guarantee optimal data transmission it is advisable to always place the radio control in its support
in a vertical position.