3-45
3.17
Main Menu 5 (Option COMM or Option PROFIBUS)
Main Menu 5 is dedicated to the serial/profibus option.
COMM A
is used to set up the
serial/profibus line and
is used for setting up the printer output. Main Menu 5 does not
appear unless an optional COMM A is installed.
3.17.1
Comunication A (Option COMM)
The
MINI CK100
has one serial channel, which can be configured using jumpers as an RS232
or an RS485 channel. The serial channel can be used for printing or for a serial communication
with an intelligent device such as a PLC or a PC.
The following screens define the communication parameters of the channel.
Default:
9600
Selections:
110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200
Default:
No
Parity
Selections:
Even Parity, Odd Parity, No Parity
Default:
1 Stop Bit
Selections
:
1 Stop Bit, 2 Stop Bits
Default:
8
Bits
Selections:
7 Bits, 8 Bits
COM A SCROLL 1
Baud Rate COM #1
> 2400 <
CHOICE ENTER
Password:Service
- COM A SCROLL 2 -
Set Parity COM #1
> No Parity <
CHOICE ENTER
Password:Service
- COM A SCROLL 3 -
Stop bit COM #1
> 1 stop bit <
CHOICE ENTER
Password:Service
- COM A SCROLL 4 -
Wordlength COM #1
> 8 bits <
CHOICE ENTER
Password:Service