3-22
3.9.10 Acquiring Tare
The TARE mode function, allows tare to be set automatically or manually in the RUN scroll.
Default:
Acquire
Choices:
Acquire,
Manual
If ACQUIRE is selected, Tare is automatically acquired when the S/R TARE key is pressed or
by digital input.
If MANUAL is selected, tare may be entered through the keypad when the S/R TARE key is
pressed .
3.10 Scale Data Scroll
3.10.1 Scale Capacity
The scale capacity is the maximum capacity of the scale.
Default:
2000.0
Min:
1
Max:
100000
3.10.2 Divisions
The division corresponding to the just entered Scale Capacity (in the example 0.1).If required,
the operator is able to alter the Scale Division to any of the available options.
Default:
0.1
Choices:
0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 0.01, 0.02, 0.05, 0.001, 0.002, 0.005
-- DISPLAY SCROLL 11 --
Tare Mode
>ACQUIRE<
CHOICE ENTER
-- SC DATA SCROLL 2 --
Max Scale Capacity
2000.0 kg
ENTER SCALE#
-- SC DATA SCROLL 3 --
Scale Divisions
>0.1<
CHOICE ENTER
Summary of Contents for Ramsey MINI CK100