3-23
3.10.3
Defining the Load Cell(s)
3.10.3.1 Number of Load Cells
Enter the number of load cells of the scale
Default:
1
Min:
1
Max:
6
3.10.3.2 Load Cell Capacity
Enter the load cell capacity as it appears on the label placet on the load cell.
English/Mixed
Metric
Default:
250.0
Lbs
Default:
100
kg
Min:
10
Lbs
Min:
1
kg
Max:
15000
Lbs
Max:
15000
kg
3.10.3.3 Load Cell Sensitivity
Enter the load cell sensitivity in mV/V as marked on the label of the load cell. Thermo Ramsey
load cells are normally 2.000 or 3.000 mV/V.
Default:
2.0
mV/V
Min:
0.500
mV/V
Max:
3.500
mV/V
-- SC DATA SCROLL 7 --
Load cell capacity
2000.0 kg
ENTER
Password:Service
-- SC DATA SCROLL 6 --
Load cell number
1
ENTER
Password: Service
-- SC DATA SCROLL 8 --
Load cell sensitivity
2.00 mV/V
ENTER
Password:Service
Summary of Contents for Ramsey MINI CK100
Page 1: ...1 Operating And Service Manual Ramsey MINI CK100 Weight Indicator MINI CK100 Part No...
Page 4: ......
Page 14: ......
Page 24: ......
Page 80: ......
Page 86: ......
Page 92: ......
Page 94: ......
Page 95: ...C 1 Appendix C Drawings Wiring Diagram CK 0000100 E001C...
Page 96: ......
Page 97: ......