4-4
4.4 Cold Start
It may be necessary to cold start the
MINI CK100
in the event memory becomes corrupted. In
the event of a cold start, you have the option of installing the factory default constants or
simply returning the instrument to its previous running state.
The cold start can be forced through the menu
DIAGNOSITCS SCROLL
(see 3.13.7)
When the following screen displays, all field entry data has been replaced by the factory default
constants.
Select the language and follow the initial setup procedures.
4.5 Load Cell Excitation and Signal Voltage
1.
Measure excitation voltage across terminal 21 negative and 20 positive in the scale
junction box. This should be 10 VDC
±
5%.
2.
If the excitation voltage is incorrect then measure the excitation voltage in the
MINI
CK100
across terminal 6 negative and the 1 positive.This should be 10 VDC
±
5%.
3.
Measure DC millivolt signal voltage across terminal 22 positive and 23 negative in the
scale junction box. This should be within 0-30 millivolts DC (3 mV/V load cell).
4.
Measure DC millivolt signal voltage across terminal 3 positive and 4 negative in the
MINI CK100
. This should be the same as Step 3 above.
5.
The millivolt output is in direct relation to weight applied. As weight is increased,
output should increase.
4.6 Lithium Battery Replacement
The
MINI CK100
volatile memory backup battery can be replaced without any special tools.
WARNING
DANGER
OF
EXPLOSION
IF
BATTERY
IS
INCORRECTLY
REPLACED.
Replace only with same or equivalent type recommended by Thermo Ramsey. Dispose of
used battery according to manufactures instruction on battery or return to Thermo Ramsey.
1.
Turn the
MINI CK100
power off at the mains.
2.
Remove the battery from its compression socket.
3.
Observe the polarity markings on the battery socket base before inserting the new battery.
4.
Insert battery
5.
Restore power to the
MINI CK100.
6.
Re-enter date and time on instrument set up.
-- MEMORY ERASED --
Choose the language
key to continue to
ITA
USA
Summary of Contents for Ramsey MINI CK100
Page 1: ...1 Operating And Service Manual Ramsey MINI CK100 Weight Indicator MINI CK100 Part No...
Page 4: ......
Page 14: ......
Page 24: ......
Page 80: ......
Page 86: ......
Page 92: ......
Page 94: ......
Page 95: ...C 1 Appendix C Drawings Wiring Diagram CK 0000100 E001C...
Page 96: ......
Page 97: ......