17
Service Guide
Pre-Trip
Every
1,000
Hours
Annual/
Yearly
Inspect/Service These Items
Electrical
•
Perform a controller Pre-trip Inspection (PTI) check.
•
•
•
Visually inspect condenser fan and evaporator fan rotation.
•
•
•
Visually inspect electrical contacts for damage or loose connections.
•
•
•
Visually inspect wire harnesses for damaged wires or connections.
•
•
Download the data logger and check data for correct logging.
•
Check operation of protection shutdown circuits.
Refrigeration
•
•
•
Check refrigerant charge.
•
•
•
Check for proper suction pressure.
•
•
•
Check compressor oil level.
•
Check compressor efficiency and pump down the refrigeration system.
•
Check discharge and suction pressures.
•
Check dehydrator for restriction or corrosion.
Structural
•
•
•
Visually inspect Unit for damaged, loose or broken parts.
•
•
•
Tighten unit, compressor and fan motor mounting bolts.
•
•
Clean entire unit including condenser and evaporator coils and defrost
drains.