Specifications
27
Defrost Termination:
Evaporator Coil Sensor*
Chill Mode: Terminates defrost when coil sensor
temperature rises to 30 C (86 F); or exceeds 18 C (65 F)
for 25 minutes
Frozen Mode: Terminates defrost when coil sensor
temperature rises to 18 C (65 F); or exceeds 8 C (46 F) for
25 minutes
Interval Timer**
Terminates defrost after 90 minutes at 60 Hz operation if
coil sensor has not terminated defrost (120 minutes at 50
Hz operation)
Compressor Shutdown (Auto Reset):
Stops Compressor
130C (266 F)
Allows Compressor Start
90 C (194 F)
Power Off
Turning unit On/Off switch OFF terminates defrost