![Texas Instruments CC2533 User Manual Download Page 114](http://html.mh-extra.com/html/texas-instruments/cc2533/cc2533_user-manual_1094592114.webp)
T1CC0
T1CC0
T1CCn
T1CCn
T1CC0
T1CCn
T1CCn
T1CCn
0000h
0 - Set Output on Compare
1 - Clear Output on Compare
5 - Clear When T1CC0, Set When T1CCn
6 - Set When T1CC0, Clear When T1CCn
2 - Toggle Output on Compare
3 - Set Output on Compare-Up,
Clear on Compare-Down
T0313-01
4 - Clear Output on Compare-Up,
Set on Compare-Down
Output Compare Mode
Figure 9-6. Output Compare Modes, Timer Up/Down Mode
114
Timer 1 (16-Bit Timer)
SWRU191C
–
April 2009
–
Revised January 2012
Copyright
©
2009
–