![Terrasat Rx 1+1 Operation Manual Download Page 77](http://html.mh-extra.com/html/terrasat/rx-1-1/rx-1-1_operation-manual_1089883077.webp)
RS485
|
5-15
For SET Commands, the format is as follows:
<address/command=XXX[CR}
Example:
<0001/CPE=1234{CR}
ASCII Mode Response Format
•
Start of Packet: > (ASCII code 62; 1 character)
•
Target Address: (4 characters)
•
Address De-limiter: / (ASCII code 47; 1 character)
•
Variable Length Data: (
n
characters)
•
End of Packet: Carriage Return (ASCII code 13; 1 character)
Example:
>0001/{Variable Length Data}{CR}
Commands and values available in ASCII mode are shown in the command set in
.