![Terrasat Rx 1+1 Operation Manual Download Page 118](http://html.mh-extra.com/html/terrasat/rx-1-1/rx-1-1_operation-manual_1089883118.webp)
D-10
|
ASCII Command/Response Structure
CIA
Description: Displays or sets the IP address of the unit. Valid values range from (but
do not include) 1.0.0.0 through 224.0.0.0. When the netmask is applied, 0 and 255 in
the last byte are excluded.
Error Responses: 1, 4, 7, 18
Default Value = 192.168.1.254
Command/Response Values:
CIA=<Dotted Decimal IP Address>
CIC
Description: Sets the SNMP community string.
Error Responses: 1, 2, 4, 5, 7
Default: public, private, trap
Command/Response Values:
CIC= public, private, trap
CID
Description: Displays the current consumption. This is a read-only command.
Error Responses: 1, 20
Response Values:
CID=<Parameter A:>,<Parameter B:>
Parameter:
0.0–25.0 Amperes
Summary of Contents for Rx 1+1
Page 1: ...Receive Redundant Systems Operations Manual 24 Hour Technical Support 1 408 782 2166 ...
Page 6: ...iv ...
Page 10: ...viii This page intentionally left blank for double sided printing ...
Page 12: ...x This page intentionally left blank for double sided printing ...
Page 20: ...1 6 Introduction This page intentionally left blank for double sided printing ...
Page 36: ...2 16 Functional Description This page intentionally left blank for double sided printing ...
Page 84: ...6 6 Troubleshooting This page intentionally left blank for double sided printing ...
Page 145: ...Screen Shots E 13 IDC Low Threshold Sets the lowest permitted level down to 100 Ma ...
Page 158: ...E 26 Web Pages This page intentionally left blank for double sided printing ...
Page 161: ...Reference Drawings F 3 Figure F 2 Fabrication Drawing FBD 20786 XXXX Rev A ...
Page 163: ...Reference Drawings F 5 Figure F 4 Top View of Rx 1 1 System Showing Connector Locations ...