![Terrasat Rx 1+1 Operation Manual Download Page 117](http://html.mh-extra.com/html/terrasat/rx-1-1/rx-1-1_operation-manual_1089883117.webp)
Common Commands
|
D-9
CAS
Description: Displays the current active alarms. Use the CAS command to display
hexadecimal values that represent the Receive and Miscellaneous alarms. See
for the meaning of the individual alarms or use CAS=1 to
display the alarm strings.
Error Responses: 1, 7
Response Values:
CAS=R:0x0010, M:0x0010 Rx Only
CCM
Description: Displays the model number and serial number of the IBUC. This is a
read-only command.
Error Responses: 1, 7, 19
Response Values:
CCM=<Model number>, <Serial number>
where
Model number is a variable string of up to 20 characters
Serial number is a variable string of up to 10 characters
CCS
Description: Displays the M&C firmware version level. This is a read-only command.
Error Responses: 1, 7, 19
Command/Response Values:
CCS=<Firmware revision string>
where
Firmware revision is a variable string of characters.
Summary of Contents for Rx 1+1
Page 1: ...Receive Redundant Systems Operations Manual 24 Hour Technical Support 1 408 782 2166 ...
Page 6: ...iv ...
Page 10: ...viii This page intentionally left blank for double sided printing ...
Page 12: ...x This page intentionally left blank for double sided printing ...
Page 20: ...1 6 Introduction This page intentionally left blank for double sided printing ...
Page 36: ...2 16 Functional Description This page intentionally left blank for double sided printing ...
Page 84: ...6 6 Troubleshooting This page intentionally left blank for double sided printing ...
Page 145: ...Screen Shots E 13 IDC Low Threshold Sets the lowest permitted level down to 100 Ma ...
Page 158: ...E 26 Web Pages This page intentionally left blank for double sided printing ...
Page 161: ...Reference Drawings F 3 Figure F 2 Fabrication Drawing FBD 20786 XXXX Rev A ...
Page 163: ...Reference Drawings F 5 Figure F 4 Top View of Rx 1 1 System Showing Connector Locations ...