![Terrasat Rx 1+1 Operation Manual Download Page 147](http://html.mh-extra.com/html/terrasat/rx-1-1/rx-1-1_operation-manual_1089883147.webp)
Screen Shots
|
E-15
•
Telnet Port
Telnet is a network protocol used to establish remote communication. Ports are
specific channels for network services. In the Rx 1+1 system, the default port is
23.
Valid values include port numbers within the range of 1 to 65535.
•
Web Server Auto Refresh
Sets the interval in seconds after which the Web page refreshes. The default is 0.
Valid values: 0 to 3600
Note:
When set to 0 (the factory default), the Web page will
not
refresh.
•
RS485/FSK Address
Sets a unique designator for the unit.
Valid values: 1 to 254
•
RS485 Baud Rate
Sets the baud rate at which data is sent. The default is 9600 baud.
Valid values include: 1200, 2400, 4800, 9600, 38400, 57600, or 115200.
•
RS485/FSK Delay
Sets the delay in msec between the end of one transmission and the beginning of
reception in half-duplex mode.
Valid values include 1 to 255, and the default value is 20.
•
SNMP Version 1.0
SNMPv1 is a communication protocol used for managing TCP/IP networks.
SNMP is used to monitor network-attached devices for conditions that require
administrative attention. When enabled, the unit will respond to SNMPv1 requests.
Options include:
-
Enable (default)
-
Disable
•
SNMP Traps
Sets the generation of SNMPv1 traps. A trap is a one-way message from a
networked device to the network management system that indicates a status
change. The device will not send a trap unless it has been configured to do so.
After receiving the message, the network manager displays it and can choose to
take an action based on the event.
Options include:
-
Enable (default)
-
Disable
Summary of Contents for Rx 1+1
Page 1: ...Receive Redundant Systems Operations Manual 24 Hour Technical Support 1 408 782 2166 ...
Page 6: ...iv ...
Page 10: ...viii This page intentionally left blank for double sided printing ...
Page 12: ...x This page intentionally left blank for double sided printing ...
Page 20: ...1 6 Introduction This page intentionally left blank for double sided printing ...
Page 36: ...2 16 Functional Description This page intentionally left blank for double sided printing ...
Page 84: ...6 6 Troubleshooting This page intentionally left blank for double sided printing ...
Page 145: ...Screen Shots E 13 IDC Low Threshold Sets the lowest permitted level down to 100 Ma ...
Page 158: ...E 26 Web Pages This page intentionally left blank for double sided printing ...
Page 161: ...Reference Drawings F 3 Figure F 2 Fabrication Drawing FBD 20786 XXXX Rev A ...
Page 163: ...Reference Drawings F 5 Figure F 4 Top View of Rx 1 1 System Showing Connector Locations ...