![Terrasat Rx 1+1 Operation Manual Download Page 60](http://html.mh-extra.com/html/terrasat/rx-1-1/rx-1-1_operation-manual_1089883060.webp)
4-2
|
Operations
Possible Alarms
Alarms occur whenever a threshold level (high or low) has been exceeded. You can
configure these threshold levels as well as the type of alarm (major, minor, or
disabled) that is caused.
Input Low Threshold
If you are experiencing an Input Low Threshold alarm,
shown on
.
with the thresholds set by using the
Remember that the input level of the online unit must be greater than the level of
the offline unit.
3. If your Rx Input level has exceeded the Input Low Threshold, you might have lost
track of the satellite.
Supply Voltage
If you are experiencing a Supply Voltage alarm,
.
2. Compare the levels with the thresholds set by using the
.
3. If your levels indicate a lack of supply voltage,
•
Check to ensure that the unit is being supplied power via the J2 and J3
connectors.
•
Check the power supply to ensure that it is not being overloaded.
An overloaded power supply can cause the short-circuit protection to activate.
Check what is connected to J4 and J5 for short circuits.
•
There could be a problem with the unit itself
In this case, contact Technical Support
Current Consumption
If you are experiencing a Current Consumption alarm,
.
2. Compare the levels with the thresholds set by using the
.
3. Verify that the levels are consistent with specifications for the LNB.
If they are not, you might have a problem with your LNB. Contact the LNB
manufacturer for support.
Summary of Contents for Rx 1+1
Page 1: ...Receive Redundant Systems Operations Manual 24 Hour Technical Support 1 408 782 2166 ...
Page 6: ...iv ...
Page 10: ...viii This page intentionally left blank for double sided printing ...
Page 12: ...x This page intentionally left blank for double sided printing ...
Page 20: ...1 6 Introduction This page intentionally left blank for double sided printing ...
Page 36: ...2 16 Functional Description This page intentionally left blank for double sided printing ...
Page 84: ...6 6 Troubleshooting This page intentionally left blank for double sided printing ...
Page 145: ...Screen Shots E 13 IDC Low Threshold Sets the lowest permitted level down to 100 Ma ...
Page 158: ...E 26 Web Pages This page intentionally left blank for double sided printing ...
Page 161: ...Reference Drawings F 3 Figure F 2 Fabrication Drawing FBD 20786 XXXX Rev A ...
Page 163: ...Reference Drawings F 5 Figure F 4 Top View of Rx 1 1 System Showing Connector Locations ...