Second Edition • Second Printing
Operator's Manual
Operating Instructions
Part No. 1311085GT
S
®
-80 XC
™
• S
®
-85 XC
™
57
8 The system will keep the engine on at high
RPM until the coolant temperature reaches 35
C°. The LCD screen will then display the
message "Standstill Regen Launch".
9 If the Regeneration process has begun
successfully, the regeneration process auto-
advances and the LCD screen displays the
message "Standstill Regen Active".
10 The regeneration process auto-advances and
once it is completed the LCD screen displays
the message "Regen Complete".
Aircraft Protection Package Operation
(if equipped)
If the platform bumper comes into contact with an
object, the machine will shut down and no
functions will operate.
Aircraft Protection Override
(Platform Controls)
1 Move and hold the aircraft
protection function override
switch.
2 Move the appropriate
function to move the
platform away from the
object.
Aircraft Protection Override
(Ground Controls)
1 Release all functions, including the function
enable button.
2 Press and hold the function
enable button to override
the protection.
3 Move the appropriate function to move the
platform away from the object.