Operator's Manual
Second Edition • Second Printing
Inspections
34
S
®
-80 XC
™
• S
®
-85 XC
™
Part No. 1311085GT
At the Ground Controls
1 Select a test area that is firm, level and free of
hazards.
2 Turn the key switch to ground control.
3 Pull out the red Emergency Stop button to the
on position.
Result: The alarm should sound at the ground
controls.
4 Start the engine. See Operating Instructions
section.
Result: The beacons (if equipped) should
flash.
Test Emergency Stop
5 Push in the red Emergency Stop button to the
off position.
Result: The engine should shut off and no
functions should operate.
6 Pull out the red Emergency Stop button to the
on position and restart the engine.
Test Machine Functions
7 Do not push the function
enable button. Attempt to
activate each boom and
platform function button.
Result: No boom and platform functions
should operate.
8 Press and hold the function enable button and
activate each boom and platform function
button.
Result: All boom and platform functions should
operate through a full cycle. The descent
alarm should sound while the boom is
lowering.
Test the Tilt Sensor
9 Press the Maintenance button
above the LCD screen.
Navigate to the Real-time Data
screen.
Result: The LCD screen should display the
chassis angle, boom angle, and platform
angle.
Summary of Contents for Genie S-80 SC
Page 78: ......