Second Edition • Second Printing
Operator's Manual
Inspections
Part No. 1311085GT
S
®
-80 XC
™
• S
®
-85 XC
™
35
Test Auxiliary Power
10 Turn the key switch to ground control and shut
the engine off.
11 Pull out the red Emergency Stop button to the
on position.
12 Simultaneously push the
auxiliary power button and
activate each boom function
button.
Note: To conserve battery power, test each
function through a partial cycle.
Result: All boom functions should operate.
13 Turn the key switch to platform control.
At the Platform Controls
Test the Tilt Sensor Alarm
14 Enter the platform and pull out the red
Emergency Stop button.
Result: The alarm should sound at the
platform controls.
Test Emergency Stop
15 Start the engine.
16 Push in the platform red Emergency Stop
button to the off position.
Result: The engine should shut off and no
functions should operate.
17 Pull out the red Emergency Stop button and
restart the engine.
Test the Horn
18 Press the horn button.
Result: The horn should sound.
Test the Foot Switch
19 Push in the platform red Emergency Stop
button to the off position.
20 Pull out the red Emergency Stop button to the
on position and do not start the engine.
21 Press down the foot switch and attempt to
start the engine by moving the start toggle
switch to either side.
Result: The engine should not start.
22 Do not press down the foot switch and restart
the engine.
Result: The engine should start.
23 Do not press down the foot switch and test
each machine function.
Result: No functions should operate.
Summary of Contents for Genie S-80 SC
Page 78: ......