Engine RPM Select
Select engine RPM using the symbols on the
control panel.
When the foot switch is not pressed, the engine
will idle at the lowest rpm.
•
Turtle symbol: Foot switch
activated low speed
•
Rabbit symbol: Foot switch
activated high speed
Generator (if equipped)
To operate the generator, move the generator
toggle switch to the on position.
Note: The generator indicator light will turn on.
The generator will turn on and the engine will
continue to run in high RPM mode.
Plug a power tool into AC power outlet located at
the platform, or turntable.
To stop the generator, move the generator toggle
switch to the off position.
Note: The generator indicator light will turn off and
the RPM will return to normal.
Operating Envelope Indicator Lights
The operating envelope indicator lights will come
on to notify the operator that a function has been
interrupted and/or an action is required by the
operator.
Raise/Retract Boom indicator
light flashing: Raise/retract the
boom until the indicator light is
off.
Lower Boom indicator light
flashing: Lower the boom until
the indicator light is off.
Machine On Incline indicator
light is on: The light is on and
the tilt alarm sounds when the
machine exceeds the tilt sensor
activation settings. Follow the
appropriate procedure below
and move the machine to a firm,
level surface.
If the tilt alarm sounds with
the platform uphill:
1 Lower the boom.
2 Retract the boom.
If the tilt alarm sounds with
the platform downhill:
1 Retract the boom.
2 Lower the boom.