October 2008
Section 4 • Repair Procedures
4 - 26
GS-30 • GS-32 • GS-46
Part No. 96316
REV C
SCISSOR COMPONENTS
6 Use a soft metal drift to remove the number 4
center pivot pins (index #2).
7 Remove the retaining fasteners from the
number 4 pivot pin (index #14) at the non-steer
end of the machine.
8 Use a soft metal drift to remove the number 4
pivot pin (index #14) from the non-steer end of
the machine. Remove the number 4 outer arm
(index #13) from the machine.
Crushing hazard. The number 4
outer arm may become
unbalanced and fall if not properly
supported when removed from the
machine.
9 Remove the number 4 cable bridge mounting
fasteners and remove the cable bridge from the
machine.
10 Attach a lifting strap from an overhead crane to
the number 4 inner arm (index #12).
11 Remove the retaining fasteners from the
number 4 pivot pin (index #3).
12 Use a soft metal drift to remove the number 4
pivot pin (index #3) at the steer end. Remove
the number 4 inner arm (index #12) from the
machine.
Crushing hazard. The number 4
inner arm may become
unbalanced and fall if not properly
supported when removed from the
machine.
13 Remove the cables from the number 3 cable
bridge and lay them off to the side.
Component damage hazard.
Cables can be damaged if they
are kinked or pinched.
14 Remove the number 3 cable bridge mounting
fasteners and remove the cable bridge from the
machine.
15 Attach a lifting strap from an overhead crane to
the number 3 outer arm (index #4) at the
ground controls side.
16 Remove the external snap rings and retaining
fasteners from the number 3 center pivot pins
(index #4).
17 Use a soft metal drift to remove the number 3
center pivot pin (index #4) at the ground control
side.
18 Remove the retaining fasteners from the
number 3 pivot pin (index #17) at the non-steer
end of the machine.
19 Use a soft metal drift to tap the number 3 pivot
pin (index #17) halfway out at the non-steer end
of the machine. Remove the number 3 outer
arm (index #16) at the ground controls side
from the machine.
Bodily injury hazard. The number
3 outer arm at the ground controls
side may become unbalanced and
fall if not properly supported when
removed from the machine.