October 2008
Section 4 • Repair Procedures
4 - 62
GS-30 • GS-32 • GS-46
Part No. 96316
REV B
12 Place the new level sensor onto the level
sensor mount bracket with the "X" on the level
sensor base closest to the long side of the level
sensor mount and the "Y" on the level sensor
base closest to the short side of the level
sensor mount.
Tip-over hazard. The level sensor
must be installed with the "X" on
the level sensor base closest to
the long side of the tilt level sensor
box and the "Y" on the level
sensor base closest to the short
side of the tilt level sensor box.
Failure to install the tilt level
sensor as instructed could result in
the machine tipping over, causing
death or serious injury.
13 Install the level sensor retaining fasteners
through the level sensor and springs, and into
the mount bracket. Tighten the fasteners and
measure the distance between the level sensor
and the level sensor mount bracket.
Result: The measurement should be
approximately
3
/
8
inch / 10 mm.
14 Connect the chassis wire harness to the level
sensor wire harness.
15 Turn the key switch to the ground control and
pull out the red Emergency Stop button to the
on position at the ground controls.
16 Adjust the level sensor retaining fasteners until
the bubble in the top of the level sensor is
centered in the circles.
Result: The tilt sensor alarm should not sound.
Steer end
GROUND CONTROLS
Non-steer end
a
limit switch
b
level sensor mount bracket
c
level sensor S7
d
alarm H5
e
level sensor retaining fastener
f
scissor chassis
17 Raise the platform slightly.
18 Return the safety arm to the stowed position.
19 Lower the platform to the stowed position.
20 Center a lifting jack under the drive chassis at
the ground controls side of the machine.
21 Raise the machine approximately
2 inches / 5 cm.
X
Y
e
f
c
b
d
a